{"canonical":"https://abierto.us/opportunities/70z085q250019226","key":"70Z085Q250019226","url":"https://abierto.us/opportunities/70z085q250019226","title":"SEQUOIA Dual Point Davit Repair","solicitation_number":"70Z085Q250019226","notice_type":"s","open":false,"response_deadline":"2025-06-06T15:00:00Z","first_posted":"2025-05-27","last_posted":"2025-05-27","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"J020","set_aside":null,"place_state":"MI","place_county":"26147","place_county_name":"St. Clair County","place_city":"2665820","place_city_name":"Port Huron","winner":null,"award_amount":null,"publications":[{"notice_id":"80ba7769f8ef4c3dac0129243b531187","title":"SEQUOIA Dual Point Davit Repair","solicitation_number":"70Z085Q250019226","notice_type":"s","base_type":"s","posted":"2025-05-27","posted_at":null,"due_at":"2025-06-06T15:00:00Z","due_date":"2025-06-06","cancelled":null,"archived":null,"archive_date":"2025-06-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/80ba7769f8ef4c3dac0129243b531187/view","enriched":false,"history":[]}],"latest_notice_id":"80ba7769f8ef4c3dac0129243b531187","first_type":"s","notices":[{"dates":{"posted":"2025-05-27","response_deadline":{"raw":"2025-06-06T08:00:00-07:00","utc":"2025-06-06T15:00:00Z","date":"2025-06-06","time":"08:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/80ba7769f8ef4c3dac0129243b531187/view"},"naics":{"codes":["336611"],"primary":"336611"},"title":"SEQUOIA Dual Point Davit Repair","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-06-06","archive_type":"auto_custom"},"contacts":[{"name":"DONNA O'NEAL","role":"primary","email":"Donna.J.O'Neal@uscg.mil","phone":"5103931145"},{"name":"GEORGE, JERAMYAH","role":"secondary","email":"JERAMYAH.W.GEORGE@USCG.MIL","phone":"5716102958"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"80ba7769f8ef4c3dac0129243b531187","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"58475bf4583716ba86cb757219f15419074afa1f4f15c54d224b3b5b8193f9c3","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"THIS IS TO BE AWARDED SOLE SOURCE STATEMENT OF WORK (SOW) BACKGROUND CGC SEQUOIA suffered a small Charlie Fire within a control panel for the Wellin Lambie Davit System. Several terminals, wires, and other components were damaged, and the DISCREP requires certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. At the request of the vendor, pictures can be sent for preliminary part requirement inquiry. Ship’s force were able to identify where the fire could have originated. REFERENCE N/A REQUIREMENTS TO PROVIDE (1) SENIOR SERVICE FIELD TECHNICIAN WORKING (8) HRS PER DAY FOR (5) WEEKDAYS ON BOARD USCGC SEQUOIA TO ACCOMPLISH WELIN LAMBIE DAVIT TWIN PIV 5.0B SYSTEM INSPECTION, REPAIR, AND TEST. PARTS: 1000-8 DIN RAIL COMPLETE ASSEMBLED -1 859-02697 HYGROSTAT -1 859-03030 RELAY -7 859-03031 RELAY BASE -7 859-03032 RELAY RETAINING CLIP -7 859-02640 TOP HAT DIN RAIL -1 859-02400 MODULAR TERMINAL -33 859-02401 MODULAR TERMINAL -18 859-02405 END CLAMP -5 859-02410 PARTITION -12 859-02437 JUMPER BAR INSULATED -5 859-02439 JUMPER BAR INSULATED -1 859-02443 JUMPER BAR INSULATED -1 859-02685 ANGLE BRACKETS -4 859-03135 PROTECTION MODULE -7 9999 FERRULES & NUMBERING -1 4.0 ADMINISTRATION. 4.1 CONTRACTOR PERSONELL 4.1.1 Qualified Personnel. The Contractor shall provide qualified personnel and subject matter experts to perform all required tasks specified in this SOW. 4.1.2 Employee Conduct. Contractor employees shall present a professional appearance, and their conduct shall not reflect discredit upon the U.S. Government, and any involved Departments or Agencies. Contractor employees shall comply with all applicable Government regulations, policies, and procedures (e.g., fire, safety, sanitation, environmental protection, security, “off limits” areas, wearing of parts of military uniforms, and possession of weapons) when visiting or working at Government facilities. 4.1.3 Conflict of Interest. The Contractor shall not employ any person who is an employee of the U.S. Government if that employment would, or would appear to cause, a conflict of interest. The Contractor shall take appropriate precautions as delineated in the Federal Acquisition Regulation (FAR) to preclude actual or apparent conflicts of interest. 4.1.4 Facility Access The contractor must provide a valid Real I.D. 4.2 PERIOD OF PERFORMANCE. 09JUN2025-13JUN2025 4.3 PLACE OF PERFORMANCE. Repair facility to be determined. 5.0 USCG POC’S CGC SEQUOIA 2700 Omar Street Port Huron, MI 48060 POC CWO Albert (Lee) Lowery, Engineer Officer (907) 487-5344 Email: Albert.L.Lowery@uscg.mil Product Line Support: ENS Marcos Saldarriaga 667-419-5729 Marcos.A.Saldarriaga@uscg.mil","origin":"extract"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"70Z085Q250019226","place_of_performance":{"zip":"48060","city":{"name":"Port Huron"},"state":{"code":"MI"},"country":{"code":"USA"}},"product_service_code":"J020"}],"due_at":"2025-06-06T15:00:00Z","due_date":"2025-06-06","closes_at":"2025-06-06T15:00:00Z","awardable":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","state":"MI","county":"26147","county_name":"St. Clair County","city":"2665820","city_name":"Port Huron","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"80ba7769f8ef4c3dac0129243b531187","description":{"text":"THIS IS TO BE AWARDED SOLE SOURCE STATEMENT OF WORK (SOW) BACKGROUND CGC SEQUOIA suffered a small Charlie Fire within a control panel for the Wellin Lambie Davit System. Several terminals, wires, and other components were damaged, and the DISCREP requires certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. At the request of the vendor, pictures can be sent for preliminary part requirement inquiry. Ship’s force were able to identify where the fire could have originated. REFERENCE N/A REQUIREMENTS TO PROVIDE (1) SENIOR SERVICE FIELD TECHNICIAN WORKING (8) HRS PER DAY FOR (5) WEEKDAYS ON BOARD USCGC SEQUOIA TO ACCOMPLISH WELIN LAMBIE DAVIT TWIN PIV 5.0B SYSTEM INSPECTION, REPAIR, AND TEST. PARTS: 1000-8 DIN RAIL COMPLETE ASSEMBLED -1 859-02697 HYGROSTAT -1 859-03030 RELAY -7 859-03031 RELAY BASE -7 859-03032 RELAY RETAINING CLIP -7 859-02640 TOP HAT DIN RAIL -1 859-02400 MODULAR TERMINAL -33 859-02401 MODULAR TERMINAL -18 859-02405 END CLAMP -5 859-02410 PARTITION -12 859-02437 JUMPER BAR INSULATED -5 859-02439 JUMPER BAR INSULATED -1 859-02443 JUMPER BAR INSULATED -1 859-02685 ANGLE BRACKETS -4 859-03135 PROTECTION MODULE -7 9999 FERRULES & NUMBERING -1 4.0 ADMINISTRATION. 4.1 CONTRACTOR PERSONELL 4.1.1 Qualified Personnel. The Contractor shall provide qualified personnel and subject matter experts to perform all required tasks specified in this SOW. 4.1.2 Employee Conduct. Contractor employees shall present a professional appearance, and their conduct shall not reflect discredit upon the U.S. Government, and any involved Departments or Agencies. Contractor employees shall comply with all applicable Government regulations, policies, and procedures (e.g., fire, safety, sanitation, environmental protection, security, “off limits” areas, wearing of parts of military uniforms, and possession of weapons) when visiting or working at Government facilities. 4.1.3 Conflict of Interest. The Contractor shall not employ any person who is an employee of the U.S. Government if that employment would, or would appear to cause, a conflict of interest. The Contractor shall take appropriate precautions as delineated in the Federal Acquisition Regulation (FAR) to preclude actual or apparent conflicts of interest. 4.1.4 Facility Access The contractor must provide a valid Real I.D. 4.2 PERIOD OF PERFORMANCE. 09JUN2025-13JUN2025 4.3 PLACE OF PERFORMANCE. Repair facility to be determined. 5.0 USCG POC’S CGC SEQUOIA 2700 Omar Street Port Huron, MI 48060 POC CWO Albert (Lee) Lowery, Engineer Officer (907) 487-5344 Email: Albert.L.Lowery@uscg.mil Product Line Support: ENS Marcos Saldarriaga 667-419-5729 Marcos.A.Saldarriaga@uscg.mil","html":null,"origin":"extract"},"contacts":[{"name":"DONNA O'NEAL","role":"primary","email":"Donna.J.O'Neal@uscg.mil","phone":"5103931145"},{"name":"GEORGE, JERAMYAH","role":"secondary","email":"JERAMYAH.W.GEORGE@USCG.MIL","phone":"5716102958"}],"place_of_performance":{"zip":"48060","city":{"name":"Port Huron"},"state":{"code":"MI"},"country":{"code":"USA"}},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"naics_codes":["336611"],"award":null,"attachments":[],"awards":[],"related":[{"key":"70Z08526Q0027652","latest_notice_id":"5f6fbbeb67564f8cb3388a9808a298d5","title":"CGC OAK WATER TIGHT DOORS, HATCHES, SCUTTLES RENEWAL","solicitation_number":"70Z08526Q0027652","notice_type":"k","first_type":"k","first_posted":"2026-09-09","last_posted":"2026-09-09","notices":1,"due_at":"2026-09-18T15:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T15:00:00Z","awardable":true,"open":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"332321","psc":"2040","set_aside":"SBA","state":"RI","county":"44005","county_name":"Newport County","city":"4449960","city_name":"Newport","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"14501MOBILEDTEFY26","latest_notice_id":"08fb697620114d2893334b77e93aef4f","title":"USCGC POLAR STAR MOBILE DTE","solicitation_number":"14501_MOBILE_DTE_FY26","notice_type":"k","first_type":"k","first_posted":"2026-08-18","last_posted":"2026-08-18","notices":1,"due_at":"2026-09-19T06:59:00Z","due_date":"2026-09-18","closes_at":"2026-09-19T06:59:00Z","awardable":true,"open":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"424720","psc":"9150","set_aside":"SBA","state":"WA","county":"53033","county_name":"King County","city":"5363000","city_name":"Seattle","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"70Z08526Q30113B00","latest_notice_id":"110c30602fbc425385ee22f46df76bdd","title":"Heater Electric","solicitation_number":"70Z08526Q30113B00","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-19T17:00:00Z","due_date":"2026-09-19","closes_at":"2026-09-19T17:00:00Z","awardable":true,"open":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"333414","psc":"4520","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"70Z08526P49025B00","latest_notice_id":"b435ed862e2d4defba65f44d93e85721","title":"Open, Inspect, Repair Cylinder Assy.","solicitation_number":"70Z08526P49025B00","notice_type":"k","first_type":"k","first_posted":"2026-09-08","last_posted":"2026-09-17","notices":2,"due_at":"2026-09-21T13:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T13:00:00Z","awardable":true,"open":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"811310","psc":"J020","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"},{"key":"70Z08526Q0026058","latest_notice_id":"ab7e411289e0488c947bfc356863c623","title":"USCGC Stratton Shaft Alignment and Bearing Reaction Check","solicitation_number":"70Z08526Q0026058","notice_type":"k","first_type":"k","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-21T15:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T15:00:00Z","awardable":true,"open":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"811310","psc":"J028","set_aside":"SBA","state":"CA","county":"06001","county_name":"Alameda County","city":"0600562","city_name":"Alameda","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}