{"canonical":"https://abierto.us/opportunities/70lche26qpfb00004","key":"70LCHE26QPFB00004","url":"https://abierto.us/opportunities/70lche26qpfb00004","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","open":false,"response_deadline":"2026-09-11T16:00:00Z","first_posted":"2026-08-31","last_posted":"2026-09-09","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"FEDERAL LAW ENFORCEMENT TRAINING CENTER","office":"FLETC PROCUREMENT CHELTENHAM OFFICE","naics":"238220","psc":"J042","set_aside":"SBA","place_state":"MD","winner":null,"award_amount":null,"publications":[{"notice_id":"af075679e7e94f3caf4b699232297741","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","base_type":"k","posted":"2026-08-31","posted_at":null,"due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/af075679e7e94f3caf4b699232297741/view","enriched":false,"history":[]},{"notice_id":"1db66ed79e1d4fd8951fe094e5bc2b47","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","base_type":"k","posted":"2026-09-02","posted_at":null,"due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1db66ed79e1d4fd8951fe094e5bc2b47/view","enriched":false,"history":[]},{"notice_id":"d76a3cdbbb41475c951cb6576178f986","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","base_type":"k","posted":"2026-09-02","posted_at":null,"due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d76a3cdbbb41475c951cb6576178f986/view","enriched":false,"history":[]},{"notice_id":"9bcdb292c772433d95ee254ad901624c","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","base_type":"k","posted":"2026-09-04","posted_at":null,"due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9bcdb292c772433d95ee254ad901624c/view","enriched":false,"history":[]},{"notice_id":"f687e995b409431e88e640f26c1f9635","title":"Boiler Inspection and Repairs","solicitation_number":"70LCHE26QPFB00004","notice_type":"k","base_type":"k","posted":"2026-09-09","posted_at":"2026-09-09T17:30:12.219Z","due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","cancelled":false,"archived":false,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f687e995b409431e88e640f26c1f9635/view","enriched":true,"history":[{"index":5,"title":"Boiler Inspection and Repairs","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T17:30:12.219Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f687e995b409431e88e640f26c1f9635","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":4,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-04T12:21:22.401Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9bcdb292c772433d95ee254ad901624c","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":3,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-02T18:32:29.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"d76a3cdbbb41475c951cb6576178f986","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":2,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-02T15:19:04.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1db66ed79e1d4fd8951fe094e5bc2b47","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":1,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T18:08:09.439Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"af075679e7e94f3caf4b699232297741","solicitation_number":"70LCHE26QPFB00004"}]}],"latest_notice_id":"f687e995b409431e88e640f26c1f9635","first_type":"k","notices":[{"dates":{"posted":"2026-08-31","response_deadline":{"raw":"2026-09-11T12:00:00-04:00","utc":"2026-09-11T16:00:00Z","date":"2026-09-11","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/af075679e7e94f3caf4b699232297741/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Boiler Inspection and Repairs","agency":{"office":{"code":"70LCHE","name":"FLETC PROCUREMENT CHELTENHAM OFFICE"},"subtier":{"code":"7015","name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto15"},"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"af075679e7e94f3caf4b699232297741","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"0d0a69f2b828db98efdb8a54e06046bf716332e4c0e0fbd5adc28609acd70ab1","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors. The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers. Bidders are responsible for verifying all site conditions and quantities prior to bid submission. The Contractor shall provide a complete inspection and troubleshooting service, which includes: Submitting a detailed assessment checklist noting all deficiencies. Providing a line-item cost estimate to correct any identified deficiencies. Ensuring the inspection covers, at a minimum: Mounting, Isolators, and Filter Components Burner and Gas Train Breeching and Combustion Air Boiler Inspection and Chemical Treatment Fan functionality Sight Glass, Water Piping, Gas Piping, and associated valves Electrical connections, including disconnect switch and safety circuits Control systems, firing sequences, and interlocks Safety controls, flame safeguards, and low water cutout Pressure and temperature gauges Testing of the safety relief valve Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70LCHE26QPFB00004","place_of_performance":{"zip":"20623","city":{"name":"Cheltenham"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-09-02","response_deadline":{"raw":"2026-09-11T12:00:00-04:00","utc":"2026-09-11T16:00:00Z","date":"2026-09-11","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1db66ed79e1d4fd8951fe094e5bc2b47/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Boiler Inspection and Repairs","agency":{"office":{"code":"70LCHE","name":"FLETC PROCUREMENT CHELTENHAM OFFICE"},"subtier":{"code":"7015","name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto15"},"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"1db66ed79e1d4fd8951fe094e5bc2b47","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"3b174ae30edc19a3d5573993b58a6cf348510e20413e5d1a7ec7f78b374fd584","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors. The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers. Bidders are responsible for verifying all site conditions and quantities prior to bid submission. The Contractor shall provide a complete inspection and troubleshooting service, which includes: Submitting a detailed assessment checklist noting all deficiencies. Providing a line-item cost estimate to correct any identified deficiencies. Ensuring the inspection covers, at a minimum: Mounting, Isolators, and Filter Components Burner and Gas Train Breeching and Combustion Air Boiler Inspection and Chemical Treatment Fan functionality Sight Glass, Water Piping, Gas Piping, and associated valves Electrical connections, including disconnect switch and safety circuits Control systems, firing sequences, and interlocks Safety controls, flame safeguards, and low water cutout Pressure and temperature gauges Testing of the safety relief valve Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70LCHE26QPFB00004","place_of_performance":{"zip":"20623","city":{"name":"Cheltenham"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-09-02","response_deadline":{"raw":"2026-09-11T12:00:00-04:00","utc":"2026-09-11T16:00:00Z","date":"2026-09-11","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d76a3cdbbb41475c951cb6576178f986/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Boiler Inspection and Repairs","agency":{"office":{"code":"70LCHE","name":"FLETC PROCUREMENT CHELTENHAM OFFICE"},"subtier":{"code":"7015","name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto15"},"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d76a3cdbbb41475c951cb6576178f986","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"a22589b063d1a072508e1b1fdda2eaf0fdab20b46fed43e3de320a22f7f0bec2","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors. The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers. Bidders are responsible for verifying all site conditions and quantities prior to bid submission. The Contractor shall provide a complete inspection and troubleshooting service, which includes: Submitting a detailed assessment checklist noting all deficiencies. Providing a line-item cost estimate to correct any identified deficiencies. Ensuring the inspection covers, at a minimum: Mounting, Isolators, and Filter Components Burner and Gas Train Breeching and Combustion Air Boiler Inspection and Chemical Treatment Fan functionality Sight Glass, Water Piping, Gas Piping, and associated valves Electrical connections, including disconnect switch and safety circuits Control systems, firing sequences, and interlocks Safety controls, flame safeguards, and low water cutout Pressure and temperature gauges Testing of the safety relief valve Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70LCHE26QPFB00004","place_of_performance":{"zip":"20623","city":{"name":"Cheltenham"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-09-04","response_deadline":{"raw":"2026-09-11T12:00:00-04:00","utc":"2026-09-11T16:00:00Z","date":"2026-09-11","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9bcdb292c772433d95ee254ad901624c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Boiler Inspection and Repairs","agency":{"office":{"code":"70LCHE","name":"FLETC PROCUREMENT CHELTENHAM OFFICE"},"subtier":{"code":"7015","name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto15"},"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"9bcdb292c772433d95ee254ad901624c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"e5ccfaf364c9045313d463bba7f18540df61913b088c771e5129ffb2e1f79084","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors. The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers. Bidders are responsible for verifying all site conditions and quantities prior to bid submission. The Contractor shall provide a complete inspection and troubleshooting service, which includes: Submitting a detailed assessment checklist noting all deficiencies. Providing a line-item cost estimate to correct any identified deficiencies. Ensuring the inspection covers, at a minimum: Mounting, Isolators, and Filter Components Burner and Gas Train Breeching and Combustion Air Boiler Inspection and Chemical Treatment Fan functionality Sight Glass, Water Piping, Gas Piping, and associated valves Electrical connections, including disconnect switch and safety circuits Control systems, firing sequences, and interlocks Safety controls, flame safeguards, and low water cutout Pressure and temperature gauges Testing of the safety relief valve Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70LCHE26QPFB00004","place_of_performance":{"zip":"20623","city":{"name":"Cheltenham"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-09-09","posted_at":"2026-09-09T17:30:12.219Z","created_at":"2026-09-09T16:48:39.728Z","modified_at":"2026-09-09T17:30:12.226Z","response_deadline":{"raw":"2026-09-11T12:00:00-04:00","utc":"2026-09-11T16:00:00Z","date":"2026-09-11","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f687e995b409431e88e640f26c1f9635/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Boiler Inspection and Repairs","agency":{"office":{"code":"70LCHE","name":"FLETC PROCUREMENT CHELTENHAM OFFICE"},"subtier":{"code":"7015","name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"organization_id":"100183294","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-09-26","archive_type":"auto15"},"history":[{"index":5,"title":"Boiler Inspection and Repairs","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T17:30:12.219Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f687e995b409431e88e640f26c1f9635","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":4,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-04T12:21:22.401Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"9bcdb292c772433d95ee254ad901624c","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":3,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-02T18:32:29.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"d76a3cdbbb41475c951cb6576178f986","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":2,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-02T15:19:04.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1db66ed79e1d4fd8951fe094e5bc2b47","solicitation_number":"70LCHE26QPFB00004","parent_opportunity_id":"af075679e7e94f3caf4b699232297741"},{"index":1,"title":"Boiler Inspection and Repairs","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T18:08:09.439Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"af075679e7e94f3caf4b699232297741","solicitation_number":"70LCHE26QPFB00004"}],"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f687e995b409431e88e640f26c1f9635","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"af075679e7e94f3caf4b699232297741","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-16T13:55:30.998725365Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"d7b5c16a819981a8a52d2aa6334f0a3b8599b904218556bfe13a0c5d1f611877","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T13:55:30.998725365Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"<p>The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.</p>\n\n<p>The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.</p>\n\n<p>Bidders are responsible for verifying all site conditions and quantities prior to bid submission.</p>\n\n<p>The Contractor shall provide a complete inspection and troubleshooting service, which includes:</p>\n\n<ul>\n\t<li>Submitting a detailed assessment checklist noting all deficiencies.</li>\n\t<li>Providing a line-item cost estimate to correct any identified deficiencies.</li>\n\t<li>Ensuring the inspection covers, at a minimum:</li>\n</ul>\n\n<ul>\n\t<li>Mounting, Isolators, and Filter Components</li>\n\t<li>Burner and Gas Train</li>\n\t<li>Breeching and Combustion Air</li>\n\t<li>Boiler Inspection and Chemical Treatment</li>\n\t<li>Fan functionality</li>\n\t<li>Sight Glass, Water Piping, Gas Piping, and associated valves</li>\n\t<li>Electrical connections, including disconnect switch and safety circuits</li>\n\t<li>Control systems, firing sequences, and interlocks</li>\n\t<li>Safety controls, flame safeguards, and low water cutout</li>\n\t<li>Pressure and temperature gauges</li>\n\t<li>Testing of the safety relief valve</li>\n</ul>\n\n<ul>\n\t<li>Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).</li>\n</ul>","text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.\n\nThe Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.\n\nBidders are responsible for verifying all site conditions and quantities prior to bid submission.\n\nThe Contractor shall provide a complete inspection and troubleshooting service, which includes:\n\n• Submitting a detailed assessment checklist noting all deficiencies.\n\n• Providing a line-item cost estimate to correct any identified deficiencies.\n\n• Ensuring the inspection covers, at a minimum:\n\n• Mounting, Isolators, and Filter Components\n\n• Burner and Gas Train\n\n• Breeching and Combustion Air\n\n• Boiler Inspection and Chemical Treatment\n\n• Fan functionality\n\n• Sight Glass, Water Piping, Gas Piping, and associated valves\n\n• Electrical connections, including disconnect switch and safety circuits\n\n• Control systems, firing sequences, and interlocks\n\n• Safety controls, flame safeguards, and low water cutout\n\n• Pressure and temperature gauges\n\n• Testing of the safety relief valve\n\n• Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70LCHE26QPFB00004","place_of_performance":{"zip":"20623","city":{"code":"15725","name":"Cheltenham"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J042"}],"due_at":"2026-09-11T16:00:00Z","due_date":"2026-09-11","closes_at":"2026-09-11T16:00:00Z","awardable":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7015","sub_name":"FEDERAL LAW ENFORCEMENT TRAINING CENTER","office_key":"o-70LCHE","office_name":"FLETC PROCUREMENT CHELTENHAM OFFICE","state":"MD","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z","principal_notice_id":"f687e995b409431e88e640f26c1f9635","description":{"text":"The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.\n\nThe Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.\n\nBidders are responsible for verifying all site conditions and quantities prior to bid submission.\n\nThe Contractor shall provide a complete inspection and troubleshooting service, which includes:\n\n• Submitting a detailed assessment checklist noting all deficiencies.\n\n• Providing a line-item cost estimate to correct any identified deficiencies.\n\n• Ensuring the inspection covers, at a minimum:\n\n• Mounting, Isolators, and Filter Components\n\n• Burner and Gas Train\n\n• Breeching and Combustion Air\n\n• Boiler Inspection and Chemical Treatment\n\n• Fan functionality\n\n• Sight Glass, Water Piping, Gas Piping, and associated valves\n\n• Electrical connections, including disconnect switch and safety circuits\n\n• Control systems, firing sequences, and interlocks\n\n• Safety controls, flame safeguards, and low water cutout\n\n• Pressure and temperature gauges\n\n• Testing of the safety relief valve\n\n• Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).","html":"<p>The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.</p>\n\n<p>The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.</p>\n\n<p>Bidders are responsible for verifying all site conditions and quantities prior to bid submission.</p>\n\n<p>The Contractor shall provide a complete inspection and troubleshooting service, which includes:</p>\n\n<ul>\n\t<li>Submitting a detailed assessment checklist noting all deficiencies.</li>\n\t<li>Providing a line-item cost estimate to correct any identified deficiencies.</li>\n\t<li>Ensuring the inspection covers, at a minimum:</li>\n</ul>\n\n<ul>\n\t<li>Mounting, Isolators, and Filter Components</li>\n\t<li>Burner and Gas Train</li>\n\t<li>Breeching and Combustion Air</li>\n\t<li>Boiler Inspection and Chemical Treatment</li>\n\t<li>Fan functionality</li>\n\t<li>Sight Glass, Water Piping, Gas Piping, and associated valves</li>\n\t<li>Electrical connections, including disconnect switch and safety circuits</li>\n\t<li>Control systems, firing sequences, and interlocks</li>\n\t<li>Safety controls, flame safeguards, and low water cutout</li>\n\t<li>Pressure and temperature gauges</li>\n\t<li>Testing of the safety relief valve</li>\n</ul>\n\n<ul>\n\t<li>Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).</li>\n</ul>","origin":"detail"},"contacts":[{"name":"Chris Dills","role":"primary","email":"chris.d.dills@fletc.dhs.gov"}],"place_of_performance":{"zip":"20623","city":{"code":"15725","name":"Cheltenham"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20588","city":"CHELTENHAM","state":"MD","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"e933ba6876734723b7af1b36631f9326","name":"Wage Determination 15-4281.txt","kind":"file","mime_type":".txt","size_bytes":44646,"posted_at":"2026-08-31T18:08:09.439Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e933ba6876734723b7af1b36631f9326/download","mirrored":false}],"awards":[],"related":[]}