# NMT Monitoring device BNOE Philips IntelliVue BIS Module

Canonical: https://abierto.us/opportunities/36c26024q0807

- Solicitation number: 36C26024Q0807
- Notice type: Sources sought
- Status: Closed. Deadline was August 7, 2024 at 3:00 AM EDT
- Department: Department of Veterans Affairs
- Contracting office: 260-Network Contract Office 20 (36C260)
- NAICS: 339112 Surgical and Medical Instrument Manufacturing
- Product or service code: 6515 Medical and Surgical Instruments, Equipment, and Supplies
- Place of performance: Seattle, Washington
- County: King County (FIPS 53033). https://abierto.us/counties/king-county-wa-53033
- City: Seattle. https://abierto.us/cities/seattle-wa-5363000
- First posted: July 31, 2024
- Last posted: July 31, 2024
- SAM.gov: https://sam.gov/workspace/contract/opp/2f0af56da77a4e79a5ada9629730d601/view

## Description

Seeking Sources for NMT Monitoring devices BNOE Philips IntelliVue BIS Module Salient Characteristics for Neuromuscular Transmission (NMT)

**Monitoring Device Functionality:** The NMT Monitoring Device shall measure the degree of neuromuscular block, assessing the level of muscle relaxation during surgical procedures, and provide quantitative data on the level of paralysis.

**Accuracy:** The device must provide accurate and reliable measurement of neuromuscular transmission through advanced techniques such as Mechanomyography (MMG), Electromyography (EMG), or Acceleromyography (AMG).

**Ease of Use:** The NMT Monitoring Device must be user-friendly, featuring a clear display and intuitive controls to ensure quick and easy operation by medical professionals.

**Safety Features:** The device must adhere to electrical safety standards (e.g., IEC 60601-1) and incorporate safety mechanisms such as audible alarms for critical events, error detection, and automatic shut-off.

**Portability:** The device should be compact and lightweight, enabling easy transportation between operating rooms and other medical settings.

**Compatibility:** The NMT Monitoring Device should be compatible with a range of electrodes, sensors, and accessories commonly used in clinical settings.

**Reporting Capabilities:** The device should generate comprehensive reports on neuromuscular transmission measurements, allowing for data analysis and documentation in patient records.

**Training and Support:** The vendor must provide initial training, ongoing technical support, and access to educational resources to ensure the effective and safe use of the NMT Monitoring Device.