{"canonical":"https://abierto.us/opportunities/36c25927q0016","key":"36C25927Q0016","url":"https://abierto.us/opportunities/36c25927q0016","title":"6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)","solicitation_number":"36C25927Q0016","notice_type":"r","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-10-15T15:00:00Z","first_posted":"2026-10-08","last_posted":"2026-10-08","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"6515","set_aside":null,"place_state":"OK","place_scope":"nationwide","site":"Oklahoma City VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"40109","place_county_name":"Oklahoma County","place_city":"4055000","place_city_name":"Oklahoma City","winner":null,"award_amount":null,"publications":[{"notice_id":"80f7b6a3bcad4b9ca8613356afa8f213","title":"6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)","solicitation_number":"36C25927Q0016","notice_type":"r","base_type":"r","posted":"2026-10-08","posted_at":"2026-10-08T17:53:10.179Z","due_at":"2026-10-15T15:00:00Z","due_date":"2026-10-15","cancelled":false,"archived":false,"archive_date":"2026-11-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/80f7b6a3bcad4b9ca8613356afa8f213/view","enriched":true,"history":[{"index":1,"title":"6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T17:53:10.179Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80f7b6a3bcad4b9ca8613356afa8f213","solicitation_number":"36C25927Q0016"}]}],"latest_notice_id":"80f7b6a3bcad4b9ca8613356afa8f213","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-10-08","posted_at":"2026-10-08T17:53:10.179Z","created_at":"2026-10-08T17:53:08.553Z","modified_at":"2026-10-08T17:53:10.179Z","response_deadline":{"raw":"2026-10-15T09:00:00-06:00","utc":"2026-10-15T15:00:00Z","date":"2026-10-15","time":"09:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/80f7b6a3bcad4b9ca8613356afa8f213/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-14","archive_type":"auto_custom"},"history":[{"index":1,"title":"6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T17:53:10.179Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80f7b6a3bcad4b9ca8613356afa8f213","solicitation_number":"36C25927Q0016"}],"contacts":[{"name":"Devin Reichert","role":"primary","email":"Devin.Reichert@va.gov","phone":"303-712-5709","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"80f7b6a3bcad4b9ca8613356afa8f213","lineage_id":"80f7b6a3bcad4b9ca8613356afa8f213","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T00:17:21.603549758Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"88a39a008f4c126e532dc85ce516a626-26\"","fetched_at":"2026-10-09T04:25:46.346911714Z","row_sha256":"2674fd0b849a379b294010a7e3e7158b2b46e71dae888e141053722110bf899d","last_modified":"2026-10-09T03:30:27Z"},"updated_at":"2026-10-10T00:17:21.603549758Z","first_seen_at":"2026-10-09T04:25:46.346911714Z"},"description":{"html":"Sources Sought Notice   Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \n\nBrand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\nQS3 0.1 mL qPCR System with Laptop\nA28566\n1\nFast 96 Well RNase P Verification Plate\n4351979\n1\nFast 96 Well Hardshell Clear Plate (20 pack)\n4483485\n1\nOptical Adhesive Covers (25 per pack)\n4360954\n1\n802.11ac/b/g/n Wi Fi Dongle\nA26774\n1\nFast 96 Well ROI & Background Plates\n4432426\n1\nPowerTrack SYBR Master Mix, 1 mL\nA46012\n1\nTaqMan Fast Advanced Master Mix, 1 mL\n4444556\n1\nSmartStart qStudio 3 Orientation\nA28806\n1\n\n\n\nSalient Characteristics: \nSystem and Consumables\nQuantStudio 3 Real-Time PCR System\nCompatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates\nSupports barcoded, 0.1 mL reaction plates\nIncludes or identifies the quantity of plates provided\nIdentifies any additional consumables required for operation\nThermal Control and Block Configuration\n96-well sample block\nAt least three independently controlled Peltier temperature zones\nProgrammable temperature difference of up to 10Â°C across the block\nMaximum temperature difference of 5Â°C between adjacent zones\nBlock temperature range of approximately 4Â°C to 99.9Â°C\nReaction Volumes and Thermal Performance\nSupports reaction volumes of approximately 10 30 ÂµL on a 0.1 mL block\nSupports reaction volumes of approximately 10 100 ÂµL on a 0.2 mL block\nMaximum ramp rate of approximately 9.0Â°C per second for the 0.1 mL block\nMaximum ramp rate of approximately 6.5Â°C per second for the 0.2 mL block\nOptical Detection and Heated Cover\nLong-life white LED light source with a median operating life of at least 60,000 hours\nCMOS imaging system for data acquisition\nData collection for each filter combination in less than two seconds\nHeated cover temperature range of approximately 50Â°C to 110Â°C\nHeated cover designed to minimize evaporation from reaction plates\nStorage, Connectivity, Power, and Reliability\nCompatible with the Connect platform\nProvides up to 1 TB of cloud-based storage\nIncludes approximately 10 GB of onboard storage\nStores approximately 1,000 5,000 standard absolute-quantification run files\nCompatible with 100 240 V electrical outlets without modification\nProvides run protection during network or power interruptions\nIncludes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs\n\n\nBrand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\niBright FL1500 Imaging System\nA44241\n1\nSmartStart iBright Orientation\nA34016\n1\n1 Preventive Maintenance visit for iBright FL1500\nZG61SCIB\n1\nBolt Welcome Pack with iBlot 3\nNW0412AI\n1\niBright Protein Standard (25 ÂµL)\nLC5605\n1\niBright FL1500 2 Year Warranty\n\n1\n\n\n\nSalient Characteristics: \nImaging Capabilities and Performance\nChemiluminescent western blot imaging\nProtein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging\nAutomatic image capture, focus, exposure, and analysis\nQuantitative band analysis and background subtraction\nHigh sensitivity, broad dynamic range, and low-light detection\nImaging of multiple samples, including up to four mini gels in one view\nCamera, Detection, Illumination, and Imaging Area\nCooled scientific-grade CCD camera\nAt least 16-bit image capture and approximately 9-megapixel resolution or higher\nAdjustable pixel binning and optical/digital zoom\nImaging area of approximately 22.5 cm by 18 cm or larger\nRemovable sample tray\nWhite-light and blue/green-light illumination\nOptional near-infrared illumination\nChemiluminescent detection, multiple filter options, and long-life LED light sources\nInterface, Software, Storage, and Connectivity\nIntegrated touchscreen and internal computer or workstation\nAutomated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis\nMolecular-weight analysis, where applicable\nTIFF, JPEG, PNG, PDF, and other common image formats\nAt least 250 GB of internal storage\nUSB and Ethernet connectivity\nOptional wireless or cloud connectivity\nSecure data transfer, user access controls, and software updates\n\nAccessories and Training\nSample tray, imaging accessories, and white screen or equivalent for stained-gel imaging\nUser manuals, quick-start guides, installation instructions, and training materials\n3. Scope: \nThe Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management.\n\n4. Delivery:\nDepartment of Veterans Affairs\nOklahoma City VA Medical Center\n921 Northeast 13th Street\nOklahoma City, OK 73104-5007      \n \nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: \nNAICS Code: 334516\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes                     No    \nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes                     No    \nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\n\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\n\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate   What percentage of the proposed product (including leases and rentals) is a:\n\n\n\nDomestic end product? _____________ (%)\n\n\n\nForeign end product? _______________ (%) Country of Origin:\n\n\n\nQuestions for Small Businesses ONLY:\n\n\n\nIf subcontracting, what added value do you offer (RFO 52.215-23): \n\n\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â  ] yes [Â  ] no\nDoes your company exceed 500 employees?  [Â  ] yes [Â  ] no   If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied?  [Â  ] yes [Â  ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?  [Â  ] yes [Â  ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â  ] yes [Â  ] no  If yes, what is the manufacturer s name? ________________ \n\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov \nSubmit your response NLT 09:00 (MST) on October, 15th, 2026;\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees.  Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","text":"Sources Sought Notice Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\n\nBrand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\nQS3 0.1 mL qPCR System with Laptop\nA28566\n1\nFast 96 Well RNase P Verification Plate\n4351979\n1\nFast 96 Well Hardshell Clear Plate (20 pack)\n4483485\n1\nOptical Adhesive Covers (25 per pack)\n4360954\n1\n802.11ac/b/g/n Wi Fi Dongle\nA26774\n1\nFast 96 Well ROI & Background Plates\n4432426\n1\nPowerTrack SYBR Master Mix, 1 mL\nA46012\n1\nTaqMan Fast Advanced Master Mix, 1 mL\n4444556\n1\nSmartStart qStudio 3 Orientation\nA28806\n1\n\nSalient Characteristics:\nSystem and Consumables\nQuantStudio 3 Real-Time PCR System\nCompatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates\nSupports barcoded, 0.1 mL reaction plates\nIncludes or identifies the quantity of plates provided\nIdentifies any additional consumables required for operation\nThermal Control and Block Configuration\n96-well sample block\nAt least three independently controlled Peltier temperature zones\nProgrammable temperature difference of up to 10Â°C across the block\nMaximum temperature difference of 5Â°C between adjacent zones\nBlock temperature range of approximately 4Â°C to 99.9Â°C\nReaction Volumes and Thermal Performance\nSupports reaction volumes of approximately 10 30 ÂµL on a 0.1 mL block\nSupports reaction volumes of approximately 10 100 ÂµL on a 0.2 mL block\nMaximum ramp rate of approximately 9.0Â°C per second for the 0.1 mL block\nMaximum ramp rate of approximately 6.5Â°C per second for the 0.2 mL block\nOptical Detection and Heated Cover\nLong-life white LED light source with a median operating life of at least 60,000 hours\nCMOS imaging system for data acquisition\nData collection for each filter combination in less than two seconds\nHeated cover temperature range of approximately 50Â°C to 110Â°C\nHeated cover designed to minimize evaporation from reaction plates\nStorage, Connectivity, Power, and Reliability\nCompatible with the Connect platform\nProvides up to 1 TB of cloud-based storage\nIncludes approximately 10 GB of onboard storage\nStores approximately 1,000 5,000 standard absolute-quantification run files\nCompatible with 100 240 V electrical outlets without modification\nProvides run protection during network or power interruptions\nIncludes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs\n\nBrand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\niBright FL1500 Imaging System\nA44241\n1\nSmartStart iBright Orientation\nA34016\n1\n1 Preventive Maintenance visit for iBright FL1500\nZG61SCIB\n1\nBolt Welcome Pack with iBlot 3\nNW0412AI\n1\niBright Protein Standard (25 ÂµL)\nLC5605\n1\niBright FL1500 2 Year Warranty\n\n1\n\nSalient Characteristics:\nImaging Capabilities and Performance\nChemiluminescent western blot imaging\nProtein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging\nAutomatic image capture, focus, exposure, and analysis\nQuantitative band analysis and background subtraction\nHigh sensitivity, broad dynamic range, and low-light detection\nImaging of multiple samples, including up to four mini gels in one view\nCamera, Detection, Illumination, and Imaging Area\nCooled scientific-grade CCD camera\nAt least 16-bit image capture and approximately 9-megapixel resolution or higher\nAdjustable pixel binning and optical/digital zoom\nImaging area of approximately 22.5 cm by 18 cm or larger\nRemovable sample tray\nWhite-light and blue/green-light illumination\nOptional near-infrared illumination\nChemiluminescent detection, multiple filter options, and long-life LED light sources\nInterface, Software, Storage, and Connectivity\nIntegrated touchscreen and internal computer or workstation\nAutomated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis\nMolecular-weight analysis, where applicable\nTIFF, JPEG, PNG, PDF, and other common image formats\nAt least 250 GB of internal storage\nUSB and Ethernet connectivity\nOptional wireless or cloud connectivity\nSecure data transfer, user access controls, and software updates\n\nAccessories and Training\nSample tray, imaging accessories, and white screen or equivalent for stained-gel imaging\nUser manuals, quick-start guides, installation instructions, and training materials\n3. Scope:\nThe Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management.\n\n4. Delivery:\nDepartment of Veterans Affairs\nOklahoma City VA Medical Center\n921 Northeast 13th Street\nOklahoma City, OK 73104-5007\n\nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:\nNAICS Code: 334516\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes No\nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes No\nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:\n\nDomestic end product? _____________ (%)\n\nForeign end product? _______________ (%) Country of Origin:\n\nQuestions for Small Businesses ONLY:\n\nIf subcontracting, what added value do you offer (RFO 52.215-23):\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â ] yes [Â ] no\nDoes your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov\nSubmit your response NLT 09:00 (MST) on October, 15th, 2026;\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25927Q0016","place_of_performance":{"zip":"73104","city":{"code":"55000","name":"Oklahoma City"},"state":{"code":"OK","name":"Oklahoma"},"street":"Department of Veterans Affairs Oklahoma City VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"921 NE 13th Street"},"product_service_code":"6515"}],"due_at":"2026-10-15T15:00:00Z","due_date":"2026-10-15","closes_at":"2026-10-15T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","state_source":null,"state_evidence":null,"site_key":"oklahoma-city-va-medical-center-ok","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-09T04:30:03.659222Z","principal_notice_id":"80f7b6a3bcad4b9ca8613356afa8f213","description":{"text":"Sources Sought Notice Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\n\nBrand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\nQS3 0.1 mL qPCR System with Laptop\nA28566\n1\nFast 96 Well RNase P Verification Plate\n4351979\n1\nFast 96 Well Hardshell Clear Plate (20 pack)\n4483485\n1\nOptical Adhesive Covers (25 per pack)\n4360954\n1\n802.11ac/b/g/n Wi Fi Dongle\nA26774\n1\nFast 96 Well ROI & Background Plates\n4432426\n1\nPowerTrack SYBR Master Mix, 1 mL\nA46012\n1\nTaqMan Fast Advanced Master Mix, 1 mL\n4444556\n1\nSmartStart qStudio 3 Orientation\nA28806\n1\n\nSalient Characteristics:\nSystem and Consumables\nQuantStudio 3 Real-Time PCR System\nCompatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates\nSupports barcoded, 0.1 mL reaction plates\nIncludes or identifies the quantity of plates provided\nIdentifies any additional consumables required for operation\nThermal Control and Block Configuration\n96-well sample block\nAt least three independently controlled Peltier temperature zones\nProgrammable temperature difference of up to 10Â°C across the block\nMaximum temperature difference of 5Â°C between adjacent zones\nBlock temperature range of approximately 4Â°C to 99.9Â°C\nReaction Volumes and Thermal Performance\nSupports reaction volumes of approximately 10 30 ÂµL on a 0.1 mL block\nSupports reaction volumes of approximately 10 100 ÂµL on a 0.2 mL block\nMaximum ramp rate of approximately 9.0Â°C per second for the 0.1 mL block\nMaximum ramp rate of approximately 6.5Â°C per second for the 0.2 mL block\nOptical Detection and Heated Cover\nLong-life white LED light source with a median operating life of at least 60,000 hours\nCMOS imaging system for data acquisition\nData collection for each filter combination in less than two seconds\nHeated cover temperature range of approximately 50Â°C to 110Â°C\nHeated cover designed to minimize evaporation from reaction plates\nStorage, Connectivity, Power, and Reliability\nCompatible with the Connect platform\nProvides up to 1 TB of cloud-based storage\nIncludes approximately 10 GB of onboard storage\nStores approximately 1,000 5,000 standard absolute-quantification run files\nCompatible with 100 240 V electrical outlets without modification\nProvides run protection during network or power interruptions\nIncludes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs\n\nBrand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\niBright FL1500 Imaging System\nA44241\n1\nSmartStart iBright Orientation\nA34016\n1\n1 Preventive Maintenance visit for iBright FL1500\nZG61SCIB\n1\nBolt Welcome Pack with iBlot 3\nNW0412AI\n1\niBright Protein Standard (25 ÂµL)\nLC5605\n1\niBright FL1500 2 Year Warranty\n\n1\n\nSalient Characteristics:\nImaging Capabilities and Performance\nChemiluminescent western blot imaging\nProtein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging\nAutomatic image capture, focus, exposure, and analysis\nQuantitative band analysis and background subtraction\nHigh sensitivity, broad dynamic range, and low-light detection\nImaging of multiple samples, including up to four mini gels in one view\nCamera, Detection, Illumination, and Imaging Area\nCooled scientific-grade CCD camera\nAt least 16-bit image capture and approximately 9-megapixel resolution or higher\nAdjustable pixel binning and optical/digital zoom\nImaging area of approximately 22.5 cm by 18 cm or larger\nRemovable sample tray\nWhite-light and blue/green-light illumination\nOptional near-infrared illumination\nChemiluminescent detection, multiple filter options, and long-life LED light sources\nInterface, Software, Storage, and Connectivity\nIntegrated touchscreen and internal computer or workstation\nAutomated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis\nMolecular-weight analysis, where applicable\nTIFF, JPEG, PNG, PDF, and other common image formats\nAt least 250 GB of internal storage\nUSB and Ethernet connectivity\nOptional wireless or cloud connectivity\nSecure data transfer, user access controls, and software updates\n\nAccessories and Training\nSample tray, imaging accessories, and white screen or equivalent for stained-gel imaging\nUser manuals, quick-start guides, installation instructions, and training materials\n3. Scope:\nThe Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management.\n\n4. Delivery:\nDepartment of Veterans Affairs\nOklahoma City VA Medical Center\n921 Northeast 13th Street\nOklahoma City, OK 73104-5007\n\nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:\nNAICS Code: 334516\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes No\nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes No\nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:\n\nDomestic end product? _____________ (%)\n\nForeign end product? _______________ (%) Country of Origin:\n\nQuestions for Small Businesses ONLY:\n\nIf subcontracting, what added value do you offer (RFO 52.215-23):\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â ] yes [Â ] no\nDoes your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov\nSubmit your response NLT 09:00 (MST) on October, 15th, 2026;\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","html":"Sources Sought Notice   Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \n\nBrand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\nQS3 0.1 mL qPCR System with Laptop\nA28566\n1\nFast 96 Well RNase P Verification Plate\n4351979\n1\nFast 96 Well Hardshell Clear Plate (20 pack)\n4483485\n1\nOptical Adhesive Covers (25 per pack)\n4360954\n1\n802.11ac/b/g/n Wi Fi Dongle\nA26774\n1\nFast 96 Well ROI & Background Plates\n4432426\n1\nPowerTrack SYBR Master Mix, 1 mL\nA46012\n1\nTaqMan Fast Advanced Master Mix, 1 mL\n4444556\n1\nSmartStart qStudio 3 Orientation\nA28806\n1\n\n\n\nSalient Characteristics: \nSystem and Consumables\nQuantStudio 3 Real-Time PCR System\nCompatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates\nSupports barcoded, 0.1 mL reaction plates\nIncludes or identifies the quantity of plates provided\nIdentifies any additional consumables required for operation\nThermal Control and Block Configuration\n96-well sample block\nAt least three independently controlled Peltier temperature zones\nProgrammable temperature difference of up to 10Â°C across the block\nMaximum temperature difference of 5Â°C between adjacent zones\nBlock temperature range of approximately 4Â°C to 99.9Â°C\nReaction Volumes and Thermal Performance\nSupports reaction volumes of approximately 10 30 ÂµL on a 0.1 mL block\nSupports reaction volumes of approximately 10 100 ÂµL on a 0.2 mL block\nMaximum ramp rate of approximately 9.0Â°C per second for the 0.1 mL block\nMaximum ramp rate of approximately 6.5Â°C per second for the 0.2 mL block\nOptical Detection and Heated Cover\nLong-life white LED light source with a median operating life of at least 60,000 hours\nCMOS imaging system for data acquisition\nData collection for each filter combination in less than two seconds\nHeated cover temperature range of approximately 50Â°C to 110Â°C\nHeated cover designed to minimize evaporation from reaction plates\nStorage, Connectivity, Power, and Reliability\nCompatible with the Connect platform\nProvides up to 1 TB of cloud-based storage\nIncludes approximately 10 GB of onboard storage\nStores approximately 1,000 5,000 standard absolute-quantification run files\nCompatible with 100 240 V electrical outlets without modification\nProvides run protection during network or power interruptions\nIncludes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs\n\n\nBrand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:\nDescription\nPart Number\nQty\niBright FL1500 Imaging System\nA44241\n1\nSmartStart iBright Orientation\nA34016\n1\n1 Preventive Maintenance visit for iBright FL1500\nZG61SCIB\n1\nBolt Welcome Pack with iBlot 3\nNW0412AI\n1\niBright Protein Standard (25 ÂµL)\nLC5605\n1\niBright FL1500 2 Year Warranty\n\n1\n\n\n\nSalient Characteristics: \nImaging Capabilities and Performance\nChemiluminescent western blot imaging\nProtein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging\nAutomatic image capture, focus, exposure, and analysis\nQuantitative band analysis and background subtraction\nHigh sensitivity, broad dynamic range, and low-light detection\nImaging of multiple samples, including up to four mini gels in one view\nCamera, Detection, Illumination, and Imaging Area\nCooled scientific-grade CCD camera\nAt least 16-bit image capture and approximately 9-megapixel resolution or higher\nAdjustable pixel binning and optical/digital zoom\nImaging area of approximately 22.5 cm by 18 cm or larger\nRemovable sample tray\nWhite-light and blue/green-light illumination\nOptional near-infrared illumination\nChemiluminescent detection, multiple filter options, and long-life LED light sources\nInterface, Software, Storage, and Connectivity\nIntegrated touchscreen and internal computer or workstation\nAutomated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis\nMolecular-weight analysis, where applicable\nTIFF, JPEG, PNG, PDF, and other common image formats\nAt least 250 GB of internal storage\nUSB and Ethernet connectivity\nOptional wireless or cloud connectivity\nSecure data transfer, user access controls, and software updates\n\nAccessories and Training\nSample tray, imaging accessories, and white screen or equivalent for stained-gel imaging\nUser manuals, quick-start guides, installation instructions, and training materials\n3. Scope: \nThe Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management.\n\n4. Delivery:\nDepartment of Veterans Affairs\nOklahoma City VA Medical Center\n921 Northeast 13th Street\nOklahoma City, OK 73104-5007      \n \nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: \nNAICS Code: 334516\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes                     No    \nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes                     No    \nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\n\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\n\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate   What percentage of the proposed product (including leases and rentals) is a:\n\n\n\nDomestic end product? _____________ (%)\n\n\n\nForeign end product? _______________ (%) Country of Origin:\n\n\n\nQuestions for Small Businesses ONLY:\n\n\n\nIf subcontracting, what added value do you offer (RFO 52.215-23): \n\n\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â  ] yes [Â  ] no\nDoes your company exceed 500 employees?  [Â  ] yes [Â  ] no   If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied?  [Â  ] yes [Â  ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?  [Â  ] yes [Â  ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â  ] yes [Â  ] no  If yes, what is the manufacturer s name? ________________ \n\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov \nSubmit your response NLT 09:00 (MST) on October, 15th, 2026;\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees.  Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","origin":"detail"},"contacts":[{"name":"Devin Reichert","role":"primary","email":"Devin.Reichert@va.gov","phone":"303-712-5709","title":"Contract Specialist"}],"place_of_performance":{"zip":"73104","city":{"code":"55000","name":"Oklahoma City"},"state":{"code":"OK","name":"Oklahoma"},"street":"Department of Veterans Affairs Oklahoma City VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"921 NE 13th Street"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"dd6aeeb1835541f7b24ec0fb98170b33","name":"36C25927Q0016.docx","kind":"file","mime_type":".docx","size_bytes":29546,"posted_at":"2026-10-08T17:53:10.179Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dd6aeeb1835541f7b24ec0fb98170b33/download","mirrored":false}],"awards":[],"related":[{"key":"36C25926Q0881","latest_notice_id":"0c92bcdd3f4a4da1bcf05c3ece64a42a","title":"S222--Grease Trap/Vault Cleaning","solicitation_number":"36C25926Q0881","notice_type":"o","first_type":"p","first_posted":"2026-09-30","last_posted":"2026-10-07","notices":4,"due_at":"2026-10-13T21:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"562998","psc":"S222","set_aside":"SDVOSBC","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"36C25926Q0622","latest_notice_id":"de9cd3451c28428cae5bf1be4f2e2516","title":"Q522--Heart Transplant Biopsies Consultation Services (Examination and Interpretation)-Light Microscopy, Immunofluorescence, and Electron Microscopy-Salt Lake City VA Health Care System","solicitation_number":"36C25926Q0622","notice_type":"r","first_type":"r","first_posted":"2026-10-08","last_posted":"2026-10-08","notices":1,"due_at":"2026-10-16T16:00:00Z","due_date":"2026-10-16","closes_at":"2026-10-16T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"621511","psc":"Q522","set_aside":null,"state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-10T00:43:22.983902Z"},{"key":"36C25926Q0831","latest_notice_id":"46b1fe29706c4a26a9680abceb8286aa","title":"Window Shades and Installation Services","solicitation_number":"36C25926Q0831","notice_type":"k","first_type":"k","first_posted":"2026-09-08","last_posted":"2026-10-07","notices":3,"due_at":"2026-10-16T16:00:00Z","due_date":"2026-10-16","closes_at":"2026-10-16T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"337920","psc":"7230","set_aside":"SDVOSBC","state":"WY","county":"56033","county_name":"Sheridan County","city":"5669845","city_name":"Sheridan","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"36C25926R00821","latest_notice_id":"57558a61f7874d50ba993cf2740d144e","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082_1","notice_type":"o","first_type":"o","first_posted":"2026-07-23","last_posted":"2026-10-02","notices":8,"due_at":"2026-10-16T16:30:00Z","due_date":"2026-10-16","closes_at":"2026-10-16T16:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-03T03:55:19.037358Z"},{"key":"36C25927Q0021","latest_notice_id":"f70bde471f6d45f999097a8a826b108b","title":"DA10--LOGICARE Patient Instructions Software and License","solicitation_number":"36C25927Q0021","notice_type":"r","first_type":"r","first_posted":"2026-10-09","last_posted":"2026-10-09","notices":1,"due_at":"2026-10-16T18:00:00Z","due_date":"2026-10-16","closes_at":"2026-10-16T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-10T03:53:14.777248Z"}],"similar_open":[{"key":"6B187Q0045900","latest_notice_id":"83c75bb9c5a94c90816bb3774f6d6e3d","title":"Fiber Coupled MgOLN Phase Modulator","solicitation_number":"6-B187-Q-00459-00","notice_type":"o","first_type":"o","first_posted":"2026-10-07","last_posted":"2026-10-07","notices":1,"due_at":"2026-10-12T14:00:00Z","due_date":"2026-10-12","closes_at":"2026-10-12T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899031","office_name":"ARGONNE NATL LAB - DOE CONTRACTOR","naics":"334516","psc":"6640","set_aside":null,"state":"IL","county":"17031","county_name":"Cook County","city":"1742795","city_name":"Lemont","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"6B187Q0046300","latest_notice_id":"08c1c67143fb445b8584ff377ecedad3","title":"Linear X-Nanopositioners","solicitation_number":"6-B187-Q-00463-00","notice_type":"o","first_type":"o","first_posted":"2026-10-07","last_posted":"2026-10-07","notices":1,"due_at":"2026-10-12T17:30:00Z","due_date":"2026-10-12","closes_at":"2026-10-12T17:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899031","office_name":"ARGONNE NATL LAB - DOE CONTRACTOR","naics":"334516","psc":"6640","set_aside":null,"state":"IL","county":"17031","county_name":"Cook County","city":"1742795","city_name":"Lemont","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"BSA475591","latest_notice_id":"6934a2eded674ad3999a3a9605ea1afe","title":"LT-SPM","solicitation_number":"BSA475591","notice_type":"o","first_type":"p","first_posted":"2026-05-01","last_posted":"2026-10-06","notices":5,"due_at":"2026-10-12T20:00:00Z","due_date":"2026-10-12","closes_at":"2026-10-12T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899033","office_name":"BROOKHAVEN NATL LAB -DOE CONTRACTOR","naics":"334516","psc":"6640","set_aside":null,"state":"NY","county":"36103","county_name":"Suffolk County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-07T04:26:30.558165Z"}],"similar_open_total":30}