{"canonical":"https://abierto.us/opportunities/36c25726r0123","key":"36C25726R0123","url":"https://abierto.us/opportunities/36c25726r0123","title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","solicitation_number":"36C25726R0123","notice_type":"p","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-10-14T15:00:00Z","first_posted":"2026-09-30","last_posted":"2026-09-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBS","place_state":"TX","place_scope":"site","site":null,"place_state_source":"sam_zip","place_evidence":null,"place_county":"48027","place_county_name":"Bell County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"30c155915b1940a393b1c1862afb7b8c","title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","solicitation_number":"36C25726R0123","notice_type":"p","base_type":"p","posted":"2026-09-30","posted_at":"2026-09-30T21:07:16.134Z","due_at":"2026-10-14T15:00:00Z","due_date":"2026-10-14","cancelled":false,"archived":false,"archive_date":"2027-01-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/30c155915b1940a393b1c1862afb7b8c/view","enriched":true,"history":[{"index":2,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:07:16.134Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"30c155915b1940a393b1c1862afb7b8c","solicitation_number":"36C25726R0123","parent_opportunity_id":"4e395796d1854dbab625821bd3d665b0"},{"index":1,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:04:00.312Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4e395796d1854dbab625821bd3d665b0","solicitation_number":"36C25726R0123"}]},{"notice_id":"4e395796d1854dbab625821bd3d665b0","title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","solicitation_number":"36C25726R0123","notice_type":"p","base_type":"p","posted":"2026-09-30","posted_at":"2026-09-30T21:04:00.312Z","due_at":"2026-10-14T15:00:00Z","due_date":"2026-10-14","cancelled":false,"archived":false,"archive_date":"2027-01-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4e395796d1854dbab625821bd3d665b0/view","enriched":true,"history":[{"index":2,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:07:16.134Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"30c155915b1940a393b1c1862afb7b8c","solicitation_number":"36C25726R0123","parent_opportunity_id":"4e395796d1854dbab625821bd3d665b0"},{"index":1,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:04:00.312Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4e395796d1854dbab625821bd3d665b0","solicitation_number":"36C25726R0123"}]}],"latest_notice_id":"4e395796d1854dbab625821bd3d665b0","first_type":"p","notices":[{"dates":{"posted":"2026-09-30","posted_at":"2026-09-30T21:07:16.134Z","created_at":"2026-09-30T21:06:37.952Z","modified_at":"2026-09-30T21:07:16.137Z","response_deadline":{"raw":"2026-10-14T10:00:00-05:00","utc":"2026-10-14T15:00:00Z","date":"2026-10-14","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/30c155915b1940a393b1c1862afb7b8c/view"},"naics":{"codes":["541310"],"primary":"541310"},"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-12","archive_type":"auto_custom"},"history":[{"index":2,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:07:16.134Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"30c155915b1940a393b1c1862afb7b8c","solicitation_number":"36C25726R0123","parent_opportunity_id":"4e395796d1854dbab625821bd3d665b0"},{"index":1,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:04:00.312Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4e395796d1854dbab625821bd3d665b0","solicitation_number":"36C25726R0123"}],"contacts":[{"name":"Ms. Makarim Abdul-Jabbar","role":"primary","email":"Makarim.abdul-jabbar@va.gov","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"30c155915b1940a393b1c1862afb7b8c","set_aside":{"code":"SDVOSBS","label":"Service-Disabled Veteran-Owned Small Business Sole Source (FAR 19.14)"},"lineage_id":"4e395796d1854dbab625821bd3d665b0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T00:05:58.791029529Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"8facd01f3611b23a0e86eb917f67391f6060d54c803976bfe791567b4c797e12","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-10-01T03:59:34.239096903Z"},"description":{"html":"<p>NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504. The applicable NAICS code is 541310 Architectural Services, with a size standard of $12.5M. Cox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent. The required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately. Cox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including: Detailed knowledge of the design rationale, engineering decisions, and analysis, Ability to perform CPS within the same technical footprint as the DOR, Willingness to assume full liability for design interpretation, corrections, or changes that may arise during construction. Any prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR. This procurement will be conducted under the authority of 41 USC &Acirc;&sect;3304(a)(5), 38 U.S. Code &Acirc;&sect; 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute). The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification &amp; Approval (J&amp;A) will be posted after award in accordance with FAR 6.301. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. No responses to this notice are requested. No solicitation will be issued. If a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to: Ms. Makarim.Abdul Jabbar@va.gov Contracting Officer, NCO 17 Telephone inquiries will not be accepted. The VA will NOT reimburse any costs associated with responding to this notice. Information received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.</p>","text":"NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504. The applicable NAICS code is 541310 Architectural Services, with a size standard of $12.5M. Cox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent. The required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately. Cox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including: Detailed knowledge of the design rationale, engineering decisions, and analysis, Ability to perform CPS within the same technical footprint as the DOR, Willingness to assume full liability for design interpretation, corrections, or changes that may arise during construction. Any prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR. This procurement will be conducted under the authority of 41 USC Â§3304(a)(5), 38 U.S. Code Â§ 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute). The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. No responses to this notice are requested. No solicitation will be issued. If a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to: Ms. Makarim.Abdul Jabbar@va.gov Contracting Officer, NCO 17 Telephone inquiries will not be accepted. The VA will NOT reimburse any costs associated with responding to this notice. Information received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25726R0123","place_of_performance":{"zip":"76504","street":"Central Texas Veterans Healthcare System 1901 Veterans Memorial Dr. Temple, TX","country":{"code":"USA"}},"product_service_code":"C1DA"},{"dates":{"posted":"2026-09-30","posted_at":"2026-09-30T21:04:00.312Z","created_at":"2026-09-30T21:03:58.106Z","modified_at":"2026-09-30T21:07:16.134Z","response_deadline":{"raw":"2026-10-14T10:00:00-05:00","utc":"2026-10-14T15:00:00Z","date":"2026-10-14","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4e395796d1854dbab625821bd3d665b0/view"},"naics":{"codes":["541310"],"primary":"541310"},"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-12","archive_type":"auto_custom"},"history":[{"index":2,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:07:16.134Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"30c155915b1940a393b1c1862afb7b8c","solicitation_number":"36C25726R0123","parent_opportunity_id":"4e395796d1854dbab625821bd3d665b0"},{"index":1,"title":"C1DA--674-19-101 Replace Boilers and Boiler Plant (CPS Only)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-30T21:04:00.312Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4e395796d1854dbab625821bd3d665b0","solicitation_number":"36C25726R0123"}],"contacts":[{"name":"Ms. Makarim Abdul-Jabbar","role":"primary","email":"Makarim.abdul-jabbar@va.gov","phone":"972-708-0836","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4e395796d1854dbab625821bd3d665b0","set_aside":{"code":"SDVOSBS","label":"Service-Disabled Veteran-Owned Small Business Sole Source (FAR 19.14)"},"lineage_id":"4e395796d1854dbab625821bd3d665b0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T00:08:14.787793091Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"6ae015ac36f2ba0afd449885df9b95b7003f22cc3a368dc67dbf14ae94bf69d0","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-10-01T03:59:34.239096903Z"},"description":{"html":"NOTICE OF INTENT TO SOLE SOURCE\nThe Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504.\nThe applicable NAICS code is 541310   Architectural Services, with a size standard of $12.5M.\nCox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent.\nThe required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately.\nCox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including:\n  Detailed knowledge of the design rationale, engineering decisions, and analysis,\n  Ability to perform CPS within the same technical footprint as the DOR,\n  Willingness to assume full liability for design interpretation, corrections, or changes that may arise during construction.\nAny prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR.\nThis procurement will be conducted under the authority of 41 USC Â§3304(a)(5), 38 U.S. Code Â§ 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute).  The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301.\nTHIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS.\nNo responses to this notice are requested. No solicitation will be issued.\nIf a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to:\nMs. Makarim.Abdul Jabbar@va.gov\nContracting Officer, NCO 17\nTelephone inquiries will not be accepted.\nThe VA will NOT reimburse any costs associated with responding to this notice.\nInformation received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.","text":"NOTICE OF INTENT TO SOLE SOURCE\nThe Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504.\nThe applicable NAICS code is 541310 Architectural Services, with a size standard of $12.5M.\nCox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent.\nThe required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately.\nCox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including:\nDetailed knowledge of the design rationale, engineering decisions, and analysis,\nAbility to perform CPS within the same technical footprint as the DOR,\nWillingness to assume full liability for design interpretation, corrections, or changes that may arise during construction.\nAny prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR.\nThis procurement will be conducted under the authority of 41 USC Â§3304(a)(5), 38 U.S. Code Â§ 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute). The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301.\nTHIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS.\nNo responses to this notice are requested. No solicitation will be issued.\nIf a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to:\nMs. Makarim.Abdul Jabbar@va.gov\nContracting Officer, NCO 17\nTelephone inquiries will not be accepted.\nThe VA will NOT reimburse any costs associated with responding to this notice.\nInformation received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25726R0123","place_of_performance":{"zip":"76504","street":"Central Texas Veterans Healthcare System 1901 Veterans Memorial Dr. Temple, TX","country":{"code":"USA"}},"product_service_code":"C1DA"}],"due_at":"2026-10-14T15:00:00Z","due_date":"2026-10-14","closes_at":"2026-10-14T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","state":"TX","county":"48027","county_name":"Bell County","city":null,"city_name":null,"country":"USA","state_source":"sam_zip","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-02T08:08:23.148393Z","principal_notice_id":"4e395796d1854dbab625821bd3d665b0","description":{"text":"NOTICE OF INTENT TO SOLE SOURCE\nThe Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504.\nThe applicable NAICS code is 541310 Architectural Services, with a size standard of $12.5M.\nCox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent.\nThe required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately.\nCox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including:\nDetailed knowledge of the design rationale, engineering decisions, and analysis,\nAbility to perform CPS within the same technical footprint as the DOR,\nWillingness to assume full liability for design interpretation, corrections, or changes that may arise during construction.\nAny prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR.\nThis procurement will be conducted under the authority of 41 USC Â§3304(a)(5), 38 U.S. Code Â§ 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute). The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301.\nTHIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS.\nNo responses to this notice are requested. No solicitation will be issued.\nIf a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to:\nMs. Makarim.Abdul Jabbar@va.gov\nContracting Officer, NCO 17\nTelephone inquiries will not be accepted.\nThe VA will NOT reimburse any costs associated with responding to this notice.\nInformation received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.","html":"NOTICE OF INTENT TO SOLE SOURCE\nThe Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504.\nThe applicable NAICS code is 541310   Architectural Services, with a size standard of $12.5M.\nCox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent.\nThe required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately.\nCox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including:\n  Detailed knowledge of the design rationale, engineering decisions, and analysis,\n  Ability to perform CPS within the same technical footprint as the DOR,\n  Willingness to assume full liability for design interpretation, corrections, or changes that may arise during construction.\nAny prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR.\nThis procurement will be conducted under the authority of 41 USC Â§3304(a)(5), 38 U.S. Code Â§ 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute).  The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301.\nTHIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS.\nNo responses to this notice are requested. No solicitation will be issued.\nIf a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to:\nMs. Makarim.Abdul Jabbar@va.gov\nContracting Officer, NCO 17\nTelephone inquiries will not be accepted.\nThe VA will NOT reimburse any costs associated with responding to this notice.\nInformation received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.","origin":"detail"},"contacts":[{"name":"Ms. Makarim Abdul-Jabbar","role":"primary","email":"Makarim.abdul-jabbar@va.gov","phone":"972-708-0836","title":"Contracting Officer"}],"place_of_performance":{"zip":"76504","street":"Central Texas Veterans Healthcare System 1901 Veterans Memorial Dr. Temple, TX","country":{"code":"USA"}},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"naics_codes":["541310"],"award":null,"attachments":[{"resource_id":"bde835461dba4296934cb655fbbf3bda","name":"36C25726R0123.docx","kind":"file","mime_type":".docx","size_bytes":17389,"posted_at":"2026-09-30T21:04:00.312Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bde835461dba4296934cb655fbbf3bda/download","mirrored":false}],"awards":[],"related":[{"key":"36C25726B0004A0001","latest_notice_id":"b3747710b2404de18ab7bd705c0f8f51","title":"Z2DA--671-24-004 NRM Replace 2nd Floor Roof","solicitation_number":"36C25726B0004A0001","notice_type":"o","first_type":"o","first_posted":"2026-08-27","last_posted":"2026-10-01","notices":4,"due_at":"2026-10-13T14:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238160","psc":"Z2DA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TO OCTOBER 13, 2026, AT 09:00 AM CDT, VIRTUAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-02T04:16:43.273742Z"},{"key":"36C25727Q0024","latest_notice_id":"48a10f1e11f04e96b0d88b4cbc2134e9","title":"F108--NTX Acid Pits Waste Removal and Maintenance","solicitation_number":"36C25727Q0024","notice_type":"k","first_type":"k","first_posted":"2026-09-22","last_posted":"2026-10-07","notices":2,"due_at":"2026-10-13T14:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"562211","psc":"F108","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"36C25727Q0007","latest_notice_id":"a4b10f2f624b4e9cac212abdc065db7f","title":"Z2FE--CTX Chapel Window Repair/Replacement","solicitation_number":"36C25727Q0007","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-10-07","notices":2,"due_at":"2026-10-13T15:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238150","psc":"Z2FE","set_aside":"SDVOSBC","state":"TX","county":"48027","county_name":"Bell County","city":"4872176","city_name":"Temple","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"36C25727Q0034","latest_notice_id":"379fe8cab7004b0e87c0fca25481c9aa","title":"4310--NEW - CTX Oil-Free Scroll Air Compressor","solicitation_number":"36C25727Q0034","notice_type":"k","first_type":"k","first_posted":"2026-10-06","last_posted":"2026-10-08","notices":2,"due_at":"2026-10-13T15:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"333912","psc":"4310","set_aside":"SBA","state":"TX","county":"48027","county_name":"Bell County","city":"4872176","city_name":"Temple","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-09T04:30:03.659222Z"},{"key":"36C25726Q0431","latest_notice_id":"ba23f0c083954f728a63977bd17275f1","title":"36C25726Q0431 504-26-006 RE FINISH B4 N AND F ADM","solicitation_number":"36C25726Q0431","notice_type":"o","first_type":"p","first_posted":"2026-06-08","last_posted":"2026-09-23","notices":7,"due_at":"2026-10-13T15:30:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T15:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238330","psc":"Z1DA","set_aside":"SDVOSBC","state":"TX","county":"48375","county_name":"Potter County","city":"4803000","city_name":"Amarillo","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T04:24:26.592861Z"}],"similar_open":[{"key":"VPCF100226GOODFELLOWAFB","latest_notice_id":"2ff9fb186be043a982849c42fdf92f0a","title":"Goodfellow AFB Automatic Robotic Dishroom","solicitation_number":"VPCF100226_GoodfellowAFB","notice_type":"r","first_type":"r","first_posted":"2026-10-02","last_posted":"2026-10-02","notices":1,"due_at":"2026-10-16T21:00:00Z","due_date":"2026-10-16","closes_at":"2026-10-16T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9000","office_name":"FA9000 AF NAF PO","naics":"541310","psc":null,"set_aside":null,"state":"TX","county":"48451","county_name":"Tom Green County","city":"4864472","city_name":"San Angelo","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Goodfellow Air Force Base","site_key":"goodfellow-air-force-base-tx","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-03T03:55:19.037358Z"},{"key":"36C25723R0049","latest_notice_id":"5073642275214db4a200d4010bd55522","title":"C1DA--NCO 17 AE Short Selection Database FY24 - FY27","solicitation_number":"36C25723R0049","notice_type":"p","first_type":"p","first_posted":"2025-01-13","last_posted":"2026-07-20","notices":2,"due_at":"2027-09-30T05:00:00Z","due_date":"2027-09-30","closes_at":"2027-09-30T05:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-02T08:08:23.148393Z"},{"key":"140D0426R0111","latest_notice_id":"21cf9eacca21437fa811f60b9931bd5b","title":"C--OSHA A/E Renovation Design and Phasing","solicitation_number":"140D0426R0111","notice_type":"o","first_type":"p","first_posted":"2026-08-25","last_posted":"2026-09-29","notices":3,"due_at":"2026-10-13T14:00:00Z","due_date":"2026-10-13","closes_at":"2026-10-13T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140D04","office_name":"IBC ACQ SVCS DIRECTORATE (00004)","naics":"541310","psc":"C211","set_aside":"SBA","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":null,"place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"}],"similar_open_total":13}