{"canonical":"https://abierto.us/opportunities/36c25526q0154","key":"36C25526Q0154","url":"https://abierto.us/opportunities/36c25526q0154","title":"VPRO Max2 Low Temp Sterilizers","solicitation_number":"36C25526Q0154","notice_type":"r","open":false,"response_deadline":"2026-01-21T17:00:00Z","first_posted":"2026-01-14","last_posted":"2026-01-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"334510","psc":"6515","set_aside":null,"place_state":"MO","place_county":"29095","place_county_name":"Jackson County","place_city":"2938000","place_city_name":"Kansas City","winner":null,"award_amount":null,"publications":[{"notice_id":"4211ea88674841a19b166c31a5acd9f8","title":"VPRO Max2 Low Temp Sterilizers","solicitation_number":"36C25526Q0154","notice_type":"r","base_type":"r","posted":"2026-01-14","posted_at":null,"due_at":"2026-01-21T17:00:00Z","due_date":"2026-01-21","cancelled":null,"archived":null,"archive_date":"2026-02-05","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4211ea88674841a19b166c31a5acd9f8/view","enriched":false,"history":[]}],"latest_notice_id":"4211ea88674841a19b166c31a5acd9f8","first_type":"r","notices":[{"dates":{"posted":"2026-01-14","response_deadline":{"raw":"2026-01-21T11:00:00-06:00","utc":"2026-01-21T17:00:00Z","date":"2026-01-21","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4211ea88674841a19b166c31a5acd9f8/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"VPRO Max2 Low Temp Sterilizers","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-02-05","archive_type":"auto15"},"contacts":[{"name":"Jon Lutmer","role":"primary","email":"Jonathan.lutmer@va.gov","phone":"4104463862"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"4211ea88674841a19b166c31a5acd9f8","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"ccbcf7b71ad991e4bccd79d9703a110a15b89cafb20e657a482970954be9a9ff","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"2. SPECIFICATIONS . Minimum of three low temperature sterilizers shall have a minimum individual dimensions of Cabinet (DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38- 5/16 x 72” (838 x 973 x 1829 mm). o Mounting single door, cabinet o System installation requires no plumbing, ventilation or air o supply – only a dedicated electrical connection is needed. A power cord is supplied for this connection o The facility space in which the vehicle can occupy is approx. 35’ x 110’. . Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heatsensitive materials because temperatures within the load currently do not exceed 55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are currently available in the United States. . Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area with a ventilation system capable of at least 10 air exchanges per hour. . VPRO MaX2 must support utility requirements: o Current 16 AMP o Minimum Circuit Breaker 20 AMPS o Use NEMA L15-20R Plug o Provide grouped or ganged circuit protection and disconnect for phase 3 power as required by NEC and local codes. o Individual power shutoffs near each machine for servicing.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0154","place_of_performance":{"zip":"64128","city":{"name":"Kansas City"},"state":{"code":"MO"},"country":{"code":"USA"}},"product_service_code":"6515"}],"due_at":"2026-01-21T17:00:00Z","due_date":"2026-01-21","closes_at":"2026-01-21T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"4211ea88674841a19b166c31a5acd9f8","description":{"text":"2. SPECIFICATIONS . Minimum of three low temperature sterilizers shall have a minimum individual dimensions of Cabinet (DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38- 5/16 x 72” (838 x 973 x 1829 mm). o Mounting single door, cabinet o System installation requires no plumbing, ventilation or air o supply – only a dedicated electrical connection is needed. A power cord is supplied for this connection o The facility space in which the vehicle can occupy is approx. 35’ x 110’. . Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heatsensitive materials because temperatures within the load currently do not exceed 55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are currently available in the United States. . Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area with a ventilation system capable of at least 10 air exchanges per hour. . VPRO MaX2 must support utility requirements: o Current 16 AMP o Minimum Circuit Breaker 20 AMPS o Use NEMA L15-20R Plug o Provide grouped or ganged circuit protection and disconnect for phase 3 power as required by NEC and local codes. o Individual power shutoffs near each machine for servicing.","html":null,"origin":"extract"},"contacts":[{"name":"Jon Lutmer","role":"primary","email":"Jonathan.lutmer@va.gov","phone":"4104463862"}],"place_of_performance":{"zip":"64128","city":{"name":"Kansas City"},"state":{"code":"MO"},"country":{"code":"USA"}},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["334510"],"award":null,"attachments":[],"awards":[],"related":[{"key":"36C25526R0166","latest_notice_id":"ef4c25eec7b748e7bb7e0fa846980cbb","title":"657-27-107JC, Replace Select Hot Water Heating System","solicitation_number":"36C25526R0166","notice_type":"p","first_type":"p","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":3,"due_at":"2026-09-21T19:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T19:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBS","state":"MO","county":"29510","county_name":"City of St. Louis","city":"2965000","city_name":"St. Louis","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C25526Q06651","latest_notice_id":"cb213b027e684eed8a0f60d3f1ecb84d","title":"Stryker Surgical Video Equipment","solicitation_number":"36C25526Q0665_1","notice_type":"p","first_type":"p","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-22T13:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T13:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"339112","psc":"6515","set_aside":null,"state":"KS","county":"20173","county_name":"Sedgwick County","city":"2079000","city_name":"Wichita","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C25526Q0665","latest_notice_id":"f0306843964640e18006a5136adf680d","title":"Stryker Surgical Video Equipment","solicitation_number":"36C25526Q0665","notice_type":"o","first_type":"o","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-22T13:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T13:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"339112","psc":"6515","set_aside":null,"state":"KS","county":"20173","county_name":"Sedgwick County","city":"2079000","city_name":"Wichita","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C25526Q0675","latest_notice_id":"8e69eb111efc49d09ba1c65960d6c6d7","title":"36C25526Q0675 Pharmacy Shelving - Robert J. Dole VAMC, Wichita","solicitation_number":"36C25526Q0675","notice_type":"o","first_type":"o","first_posted":"2026-09-17","last_posted":"2026-09-17","notices":1,"due_at":"2026-09-22T16:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"337215","psc":"7125","set_aside":"SBA","state":"KS","county":"20173","county_name":"Sedgwick County","city":"2079000","city_name":"Wichita","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"},{"key":"36C25526Q0653","latest_notice_id":"a1706a80f22a42e0b17deef831174a31","title":"Rapid ID and AST System","solicitation_number":"36C25526Q0653","notice_type":"o","first_type":"o","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-22T18:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T18:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"334516","psc":"6640","set_aside":"SBA","state":"MO","county":"29510","county_name":"City of St. Louis","city":"2965000","city_name":"St. Louis","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}