# Walk-through Ferromagnetic Dual Detector System

Canonical: https://abierto.us/opportunities/36c25524q0433

- Solicitation number: 36C25524Q0433
- Notice type: Solicitation
- Status: Awarded to Meak Solutions LLC
- Department: Department of Veterans Affairs
- Contracting office: 255-Network Contract Office 15 (36C255)
- NAICS: 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Product or service code: 6525 X-Ray Equipment and Supplies: Medical, Dental, Veterinary
- Set-aside: Service-disabled veteran-owned small business set-aside
- Place of performance: Marion, Illinois
- County: Williamson County (FIPS 17199). https://abierto.us/counties/williamson-county-il-17199
- City: Marion. https://abierto.us/cities/marion-il-1746916
- First posted: June 10, 2024
- Last posted: June 10, 2024
- SAM.gov: https://sam.gov/workspace/contract/opp/5f718355173d4da3a4efc69428342865/view

## Description

Statement of Requirement Replacement including installation of the walk-through ferromagnetic dual detector system with equivalent system for notification of MR projectile hazards. Ferromagnetic detection system must have adjustable acoustic and multiple location optical alarm capabilities with technology designed to decrease alarm fatigue and false- positive notifications. System shall have operator programable sensitivity limitation settings.

Detector(s) able to be mounted to entrance doorway of the current design for the magnet room (zone 3). Consideration of structural factors accordant for product include ability to mount on outside of cased opening with a seven (7) inch inset with permanent hardwired sign located eight (8) inches above door frame. The product shall be compatible for door with outswing operation only. See Appendix Basis of Design Product design consistent to existing position of power supply at 14 inches from framed casing of door.

Must have standard AC power with no special requirements. Detector range must accommodate the seventy-two (72) inch high by fifty-three (53) inch wide coverage area. Designed to withstand potential impact of hospital equipment during patient transfers with MR safe equipment. On-site training for staff shall be provided for safe operation, problem-solving, and information on technical support.

System must be ferromagnetic detector system designed to alarm on only ferromagnetic objects, shall not accept a metal detector designed to alarm on both ferrous and non- ferrous metal types. Complies with IEC 60601-1-8 AMD2:2020

Conforms to IEC 60101-1:2005 medical device specification requirements (the Ferromagnetic detectors are not considered to be medical devices; however, they are an integral part of the medical environment. As such, it is highly important that the power supply used in the detectors complies with standards for medical equipment used by the FDA, UL, as well as agencies around the world).

## Award on USAspending

- Recipient: Meak Solutions LLC (UEI XKHXVFCXS4R9)
- Contract: 36C25524P0525, purchase order
- Obligated: $34,998.00
- Competition: Competed Under SAP, 1 offers received
- Link: solicitation number 36C25524Q0433 equals the FPDS solicitation identifier; same awarding office 36C255 (high confidence)
- Record: https://www.usaspending.gov/award/CONT_AWD_36C25524P0525_3600_-NONE-_-NONE-/


## Publications

- June 10, 2024: Solicitation, due June 17, 2024 at 12:00 PM EDT. Notice 5f718355173d4da3a4efc69428342865. https://sam.gov/workspace/contract/opp/5f718355173d4da3a4efc69428342865/view

## Points of contact

- Jon Lutmer, Jonathan.lutmer@va.gov, 4104463862

---
Source: SAM.gov Contract Opportunities bulk extract and USAspending.gov award data. Confirm deadlines on SAM.gov before responding. Cite https://abierto.us/opportunities/36c25524q0433.
