{"canonical":"https://abierto.us/opportunities/36c24524b0022","key":"36C24524B0022","url":"https://abierto.us/opportunities/36c24524b0022","title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","solicitation_number":"36C24524B0022","notice_type":"a","open":false,"response_deadline":"2024-11-06T19:00:00Z","first_posted":"2024-08-15","last_posted":"2025-02-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","place_state":"MD","place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":"T.C.I. CONSTRUCTION & MANAGEMENT CO., INC.","award_amount":"1144000.00","publications":[{"notice_id":"3e5e17e4b0b64f1798242f3c46c9d7ab","title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","solicitation_number":"36C24524B0022","notice_type":"p","base_type":"p","posted":"2024-08-15","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2024-10-14","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3e5e17e4b0b64f1798242f3c46c9d7ab/view","enriched":false,"history":[]},{"notice_id":"d6641d2f84934819a0218d46b627eb4f","title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","solicitation_number":"36C24524B0022","notice_type":"o","base_type":"p","posted":"2024-09-26","posted_at":null,"due_at":"2024-11-06T19:00:00Z","due_date":"2024-11-06","cancelled":null,"archived":null,"archive_date":"2025-01-05","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d6641d2f84934819a0218d46b627eb4f/view","enriched":false,"history":[]},{"notice_id":"2168c3511fb04622aea90b9408d91270","title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","solicitation_number":"36C24524B0022","notice_type":"o","base_type":"o","posted":"2024-10-22","posted_at":null,"due_at":"2024-11-06T19:00:00Z","due_date":"2024-11-06","cancelled":null,"archived":null,"archive_date":"2024-12-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2168c3511fb04622aea90b9408d91270/view","enriched":false,"history":[]},{"notice_id":"9ddff200abdc43d7a8add47e335f4900","title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","solicitation_number":"36C24524B0022","notice_type":"a","base_type":"a","posted":"2025-02-12","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2025-04-13","award_number":"36C24525C0041","awardee_name":"T.C.I. CONSTRUCTION & MANAGEMENT CO., INC. TINTON FALLS 07724 JIB","amount":"1144000.00","link_sam":"https://sam.gov/workspace/contract/opp/9ddff200abdc43d7a8add47e335f4900/view","enriched":false,"history":[]}],"latest_notice_id":"9ddff200abdc43d7a8add47e335f4900","first_type":"p","notices":[{"dates":{"posted":"2024-08-15"},"links":{"sam":"https://sam.gov/workspace/contract/opp/3e5e17e4b0b64f1798242f3c46c9d7ab/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-14","archive_type":"auto_custom"},"contacts":[{"name":"Dirk Webb","role":"primary","email":"Dirk.Webb@va.gov","phone":"(304) 268-7446 ext 7621","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"3e5e17e4b0b64f1798242f3c46c9d7ab","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5842b817663f0bd138161bb9cb595b85a4ea12c0055ae483099990987c8c63d0","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Information Only, Pre-Solicitation Notice Scope of Work NRM Project No. 512-24-122 Structural Steel Fireproofing GENERAL SCOPE OF WORK: The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Baltimore Campus. Fire Proofing Apply approved fireproofing material to the exposed structural beams in all areas in accordance with section 2.1 in the Technical Memorandum Balt VAMC Steel Fire Proofing document. Contractor shall clear items away from areas where fireproofing is to be applied and return them to previous positions after application. See specifications and all other drawings for additional details. Requirements prior to work Permits (i.e., hot work, containment barriers, ICRA barriers,) see specs and project s ICRA/PCRA for more details. Submittals (i.e., fireproofing material) shall be submitted and approved by the VA prior to use. See specs for more details. Subcontractor POCs and certifications shall be submitted and approved by the VA prior to use. See specs for more details. A/E Inspection Report Work See section 2.1 in the Technical Memorandum Balt VAMC Steel Fire Proofing document for all work. Additional requirements include but not limited to: Fireproofing of exposed beams in the interstitial spaces Fireproofing of exposed beams in the service bays Assumptions Exposed steel in any areas not accessible in section 2.1 of the Technical Memorandum Balt VAMC Steel Fire Proofing document shall be fireproofed. Contractor shall honor the recommendations from ECS in sections 4.0 and 5.0 of the Technical Memorandum Balt VAMC Steel Fire Proofing document. Work will be completed in 150 calendar days from Notice To Proceed.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24524B0022","place_of_performance":{"zip":"21201","street":"Baltimore VAMC 10 North Greene Street Baltimore MD","country":{"code":"USA"}},"product_service_code":"Z1DA"},{"dates":{"posted":"2024-09-26","response_deadline":{"raw":"2024-11-06T14:00:00-05:00","utc":"2024-11-06T19:00:00Z","date":"2024-11-06","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d6641d2f84934819a0218d46b627eb4f/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-01-05","archive_type":"auto_custom"},"contacts":[{"name":"Dirk A Webb","role":"primary","email":"Dirk.Webb@va.gov","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"d6641d2f84934819a0218d46b627eb4f","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"696b857358cc9e57491477f6848f9a9191e41ef697046bce379079bb8251c4e7","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Structural Steel Fireproofing","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24524B0022","product_service_code":"Z1DA"},{"dates":{"posted":"2024-10-22","response_deadline":{"raw":"2024-11-06T14:00:00-05:00","utc":"2024-11-06T19:00:00Z","date":"2024-11-06","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2168c3511fb04622aea90b9408d91270/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-12-06","archive_type":"auto_custom"},"contacts":[{"name":"Dirk A Webb","role":"primary","email":"Dirk.Webb@va.gov","title":"Contract Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"2168c3511fb04622aea90b9408d91270","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T19:12:38.374141Z","row_sha256":"38de7d323d1cf762007250d945bc25b7baa2c478b885e9f3955ec9bf37c7db5a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T19:12:38.374141Z","first_seen_at":"2026-09-16T19:12:38.374141Z"},"description":{"text":"RFIs Received October 17, 2024 VA Response Sent October 22, 2024, by Mikaela Kaufman SOW 1C states \"See specifications and all other drawings for additional details.\" There were no specifications or drawings included for this project. Based on the information provided, there is no way for the contractor to accurately determine the size of the columns and beams which is necessary to accurately quantify the amount of fireproofing needed. Question: Are there existing as-built drawings that could be provided? The existing drawings available for reference of the beams/columns within the hospital's spaces are the original framing plans. They're available and will be provided. In order to accurately understand the amount of fireproofing needed, we need to understand the size of the beams and columns to be fireproofed. Question: If as-builts will not be provided, can the sizes of the exposed columns and beams to be fireproofed be provided? The beam type and length of the beams are noted within the framing plans provided. SOW 1C states \"See specifications and all other drawings for additional details.\" SOW 2A, 2B, and 2C reference permits, submittals, and subcontractor POCs and certifications and all state \"See specs for more details.\" The VA has said references to drawings and specifications were meant to reference the Technical Memorandum, but that does not include the referenced information. Question: Will specifications be provided for this project? Specifically, we are seeking requirements for general conditions, ICRA, and fireproofing. Yes, specifications and condition requirements will be provided for this project. SOW 4A states \"Exposed steel in any areas not accessible in section 2.1 of the \"Technical Memorandum Balt VAMC Steel Fireproofing\" document shall be fireproofed. There are 3 areas in the technical memorandum that state \"could not access this area.\" There is no way for the contractor to quantify the work in these areas based on the information provided. Question: Can allowances or assumed quantities be provided for these areas? Any assumptions that are be made must be done by referencing the site drawings that are being provided. The ECS report lists various areas with exposed columns and beams. These spaces are delineated by floor & by quad. For example, there are beams listed in Quads A, B, C & D for the interstitial spaces between floors 1 & 2. Question: Will all quads (A, B, C, & D) be accessible through the same door for that floor or will each Quad have its own access door? Each quadrant of the VA has its own access doors into the interstitial spaces located within the stairwells. Access to different quads within the interstitial site is dependent on the internal conditions of said interstitial space (for example, passage between one quadrant to another within a floor s interstitial space might not be possible due to the structure of the HVAC and/or plumbing fixtures within the space). There are many different areas listed in the ECS report, but no way to determine how many points of entry there will be to access these spaces. Question: Considering that ICRA measures will need to be provided at each entry point to protect the hospital s occupants, can the VA provide the total quantity of entries that will require ICRA measures? All entries that are to be used by the contractors will need to be protected to the satisfaction of the ICRA requirements. Referencing the attached ICRA, the main concerns involving this project are keeping dust from travelling out of the interstitial spaces with contractor movement and maintaining a clean environment after the completion of the work. There are no requirements for ICRA barriers or negative pressure.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24524B0022","product_service_code":"Z1DA"},{"award":{"date":"2025-02-11","amount":"1144000.00","number":"36C24525C0041","awardee":{"raw":"T.C.I. CONSTRUCTION & MANAGEMENT CO., INC. TINTON FALLS 07724 JIB","name":"T.C.I. CONSTRUCTION & MANAGEMENT CO., INC. TINTON FALLS 07724 JIB"}},"dates":{"posted":"2025-02-12","award_date":"2025-02-11"},"links":{"sam":"https://sam.gov/workspace/contract/opp/9ddff200abdc43d7a8add47e335f4900/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-04-13","archive_type":"auto_custom"},"contacts":[{"name":"Dirk A Webb","role":"primary","email":"dirk.webb@va.gov","phone":"(304) 268-7446 ext 7621","title":"Dirk Webb"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"9ddff200abdc43d7a8add47e335f4900","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4e0784a4788081b16d3f758b45ba5d037ed750163f5adb7c0f7e8da224692349","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24524B0022","product_service_code":"Z1DA"}],"due_at":"2024-11-06T19:00:00Z","due_date":"2024-11-06","closes_at":"2024-11-06T19:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","winner_key":"NCKSUBXHEF68","amount":"1144000.00","linked_awards":4,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"2168c3511fb04622aea90b9408d91270","description":{"text":"RFIs Received October 17, 2024 VA Response Sent October 22, 2024, by Mikaela Kaufman SOW 1C states \"See specifications and all other drawings for additional details.\" There were no specifications or drawings included for this project. Based on the information provided, there is no way for the contractor to accurately determine the size of the columns and beams which is necessary to accurately quantify the amount of fireproofing needed. Question: Are there existing as-built drawings that could be provided? The existing drawings available for reference of the beams/columns within the hospital's spaces are the original framing plans. They're available and will be provided. In order to accurately understand the amount of fireproofing needed, we need to understand the size of the beams and columns to be fireproofed. Question: If as-builts will not be provided, can the sizes of the exposed columns and beams to be fireproofed be provided? The beam type and length of the beams are noted within the framing plans provided. SOW 1C states \"See specifications and all other drawings for additional details.\" SOW 2A, 2B, and 2C reference permits, submittals, and subcontractor POCs and certifications and all state \"See specs for more details.\" The VA has said references to drawings and specifications were meant to reference the Technical Memorandum, but that does not include the referenced information. Question: Will specifications be provided for this project? Specifically, we are seeking requirements for general conditions, ICRA, and fireproofing. Yes, specifications and condition requirements will be provided for this project. SOW 4A states \"Exposed steel in any areas not accessible in section 2.1 of the \"Technical Memorandum Balt VAMC Steel Fireproofing\" document shall be fireproofed. There are 3 areas in the technical memorandum that state \"could not access this area.\" There is no way for the contractor to quantify the work in these areas based on the information provided. Question: Can allowances or assumed quantities be provided for these areas? Any assumptions that are be made must be done by referencing the site drawings that are being provided. The ECS report lists various areas with exposed columns and beams. These spaces are delineated by floor & by quad. For example, there are beams listed in Quads A, B, C & D for the interstitial spaces between floors 1 & 2. Question: Will all quads (A, B, C, & D) be accessible through the same door for that floor or will each Quad have its own access door? Each quadrant of the VA has its own access doors into the interstitial spaces located within the stairwells. Access to different quads within the interstitial site is dependent on the internal conditions of said interstitial space (for example, passage between one quadrant to another within a floor s interstitial space might not be possible due to the structure of the HVAC and/or plumbing fixtures within the space). There are many different areas listed in the ECS report, but no way to determine how many points of entry there will be to access these spaces. Question: Considering that ICRA measures will need to be provided at each entry point to protect the hospital s occupants, can the VA provide the total quantity of entries that will require ICRA measures? All entries that are to be used by the contractors will need to be protected to the satisfaction of the ICRA requirements. Referencing the attached ICRA, the main concerns involving this project are keeping dust from travelling out of the interstitial spaces with contractor movement and maintaining a clean environment after the completion of the work. There are no requirements for ICRA barriers or negative pressure.","html":null,"origin":"extract"},"contacts":[{"name":"Dirk A Webb","role":"primary","email":"dirk.webb@va.gov","phone":"(304) 268-7446 ext 7621","title":"Dirk Webb"}],"place_of_performance":null,"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["236220"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_36C24525C0041_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24525C0041_3600_-NONE-_-NONE-/","piid":"36C24525C0041","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"NCKSUBXHEF68","recipient_name":"T.C.I. CONSTRUCTION & MANAGEMENT CO., INC.","recipient_uei":"NCKSUBXHEF68","recipient_cage":"5MWV4","recipient_city":"TINTON FALLS","recipient_state":"NJ","sub_name":"Department of Veterans Affairs","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","office_key":"o-36C245","first_action_date":"2025-02-11","last_action_date":"2025-04-11","actions":2,"obligated":"1144000.00","current_total_value":"1144000.00","potential_total_value":"1144000.00","naics":"236220","psc":"Z1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":1,"description":"SPRAYING FIREPROOFING ON EXPOSED STEEL MEMBERS.","method":"piid","confidence":"high","evidence":["award number 36C24525C0041 equals the contract number","same awarding office 36C245"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24527Q0788","latest_notice_id":"8ccc8a2efc54471e9d95cd9806d98fa5","title":"DME AND RELATED SERVICES","solicitation_number":"36C24527Q0788","notice_type":"o","first_type":"o","first_posted":"2026-09-08","last_posted":"2026-09-17","notices":2,"due_at":"2026-09-21T14:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T14:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"621610","psc":"Q201","set_aside":"SBA","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"},{"key":"36C24526Q0819","latest_notice_id":"05ce94ef188f4775bf6d3ec8e750ab78","title":"Baltimore VAMC Washer/Decontamination","solicitation_number":"36C24526Q0819","notice_type":"k","first_type":"k","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C24526Q0814","latest_notice_id":"87e2a40e236f43488457d299a181ac5b","title":"DG11--Baltimore, Loch Raven, and Perry Point Guest Wi-Fi","solicitation_number":"36C24526Q0814","notice_type":"o","first_type":"p","first_posted":"2026-09-01","last_posted":"2026-09-16","notices":2,"due_at":"2026-09-23T14:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T14:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"517111","psc":"DG11","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"36C24526Q0844","latest_notice_id":"489b4c0a7070421080d6db88ac6b4519","title":"S119--Cable Services, Perry Point VAMC","solicitation_number":"36C24526Q0844","notice_type":"o","first_type":"o","first_posted":"2026-09-17","last_posted":"2026-09-17","notices":1,"due_at":"2026-09-23T15:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T15:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"517410","psc":"S119","set_aside":"SBA","state":"MD","county":"24015","county_name":"Cecil County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"},{"key":"36C24526Q0841","latest_notice_id":"64ed5d9eaebe4837bcef06235e8b156e","title":"J065--NOTICE OF INTENT TO SOLE SOURCE - PREVENTATIVE MAINTENANCE AND SERVICE CONTRACT FOR A TECNIPLAST CAGE WASHER BALTIMORE VA MEDICAL CENTER","solicitation_number":"36C24526Q0841","notice_type":"p","first_type":"p","first_posted":"2026-09-16","last_posted":"2026-09-16","notices":2,"due_at":"2026-09-24T14:00:00Z","due_date":"2026-09-24","closes_at":"2026-09-24T14:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"811210","psc":"J065","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"}]}