{"canonical":"https://abierto.us/opportunities/36c24224r0032","key":"36C24224R0032","url":"https://abierto.us/opportunities/36c24224r0032","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"a","open":false,"response_deadline":"2024-07-09T19:00:00Z","first_posted":"2024-05-01","last_posted":"2024-09-27","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","place_state":"NY","place_county":"36069","place_county_name":"Ontario County","place_city":"3612144","place_city_name":"Canandaigua","winner":"SERVIAM CONSTRUCTION LLC","award_amount":"21627110.00","publications":[{"notice_id":"71e1a292695244a4915067e5191f200a","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"p","base_type":"p","posted":"2024-05-01","posted_at":null,"due_at":"2024-05-16T19:00:00Z","due_date":"2024-05-16","cancelled":null,"archived":null,"archive_date":"2024-08-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/71e1a292695244a4915067e5191f200a/view","enriched":false,"history":[]},{"notice_id":"7f12df45c9514ad0977ae0d3de59b545","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"p","posted":"2024-05-16","posted_at":null,"due_at":"2024-06-21T19:00:00Z","due_date":"2024-06-21","cancelled":null,"archived":null,"archive_date":"2024-09-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7f12df45c9514ad0977ae0d3de59b545/view","enriched":false,"history":[]},{"notice_id":"beb8d772f3874c43a6a17ab92e93c63c","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-05-17","posted_at":null,"due_at":"2024-06-28T19:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2024-07-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/beb8d772f3874c43a6a17ab92e93c63c/view","enriched":false,"history":[]},{"notice_id":"fdcec53acdf3498fbc474f22a8e534a0","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-07","posted_at":null,"due_at":"2024-06-28T19:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2024-07-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fdcec53acdf3498fbc474f22a8e534a0/view","enriched":false,"history":[]},{"notice_id":"96152c3bf0e3450dba6af9f38c68331a","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-13","posted_at":null,"due_at":"2024-06-28T19:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2024-07-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/96152c3bf0e3450dba6af9f38c68331a/view","enriched":false,"history":[]},{"notice_id":"958a14cd910f49a68ef8d2eb33f40287","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-14","posted_at":null,"due_at":"2024-06-28T19:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2024-07-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/958a14cd910f49a68ef8d2eb33f40287/view","enriched":false,"history":[]},{"notice_id":"9ec594bf402a4fb28916950fa68e1a70","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-20","posted_at":null,"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","cancelled":null,"archived":null,"archive_date":"2024-08-08","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9ec594bf402a4fb28916950fa68e1a70/view","enriched":false,"history":[]},{"notice_id":"3a0b86afca944dcebc26494aa33c6a84","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-26","posted_at":null,"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","cancelled":null,"archived":null,"archive_date":"2024-08-08","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3a0b86afca944dcebc26494aa33c6a84/view","enriched":false,"history":[]},{"notice_id":"fef6ddfba41b42849b66faaf3338de11","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-27","posted_at":null,"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","cancelled":null,"archived":null,"archive_date":"2024-08-08","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fef6ddfba41b42849b66faaf3338de11/view","enriched":false,"history":[]},{"notice_id":"82b3e955e7df4859885d83c62fd3665c","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-06-28","posted_at":null,"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","cancelled":null,"archived":null,"archive_date":"2024-08-08","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/82b3e955e7df4859885d83c62fd3665c/view","enriched":false,"history":[]},{"notice_id":"95335920282d46ecae605612639df0e5","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"o","base_type":"o","posted":"2024-07-02","posted_at":null,"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","cancelled":null,"archived":null,"archive_date":"2024-08-08","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/95335920282d46ecae605612639df0e5/view","enriched":false,"history":[]},{"notice_id":"9f58c4250c52443789802e6da0780d4b","title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","solicitation_number":"36C24224R0032","notice_type":"a","base_type":"a","posted":"2024-09-27","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2025-01-04","award_number":"36C24224C0131","awardee_name":"SERVIAM CONSTRUCTION LLC ALTOONA 16601","amount":"21627110.00","link_sam":"https://sam.gov/workspace/contract/opp/9f58c4250c52443789802e6da0780d4b/view","enriched":false,"history":[]}],"latest_notice_id":"9f58c4250c52443789802e6da0780d4b","first_type":"p","notices":[{"dates":{"posted":"2024-05-01","response_deadline":{"raw":"2024-05-16T15:00:00-04:00","utc":"2024-05-16T19:00:00Z","date":"2024-05-16","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/71e1a292695244a4915067e5191f200a/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-23","archive_type":"auto_custom"},"contacts":[{"name":"Veronica Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","phone":"716-862-7461 ext. 22443","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"71e1a292695244a4915067e5191f200a","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"f085ce9b7c27cd2370abce801048f2a2b86537cd3ceb3684346d5252d52031f4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"THIS IS A PRE-SOLICITATION NOTICE SYNOPSIZING AN UPCOMING COMPETITIVE SOLICITATION SATISFYING THE REQUIREMENTS OF FAR 5.201 AND 5.203 AN INVITATION FOR BIDS WILL BE POSTED ON OR ABOUT MAY 16, 2024 BOILER REPLACEMENT PROJECT, Canandaigua VA Medical Center: Procurement Number: 36C24224R0032; Project Number: 528A5-20-502 The Canandaigua VA Medical Center (VAMC) will be posting a solicitation to provide all labor, materials, tools, equipment, and supervision necessary to perform work under project number 528A5-20-502 titled Boiler Replacement Project. The general scope of this project is to construct and commission replacement steam boilers and their ancillary equipment. The intent is to provide the new complete boiler system in the building 12 addition, including all piping, equipment, and controls. The new system will be readily switched over to operation without removing the current system. Once the new system is operational, the contents of the original boiler plant will be decommissioned, and equipment and piping not needed will be removed. This will include remediation of hazardous materials. After the original boiler plant equipment is removed, the area will be renovated into a workshop space. The space previously used as a fuel bunker on the east end of Building 12 will be converted to a two-level storage area. All work will be accomplished on the Canandaigua VAMC campus as indicated in the specifications and drawings. The NAICS code for this procurement is 238220 with a small business size standard of $19 million. The magnitude of this project is more than $10,000,000.00. A 20% bid bond will be required and must be submitted with the bid. This project is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","place_of_performance":{"zip":"14424","city":{"name":"Canandaigua"},"state":{"code":"NY"},"street":"Canandaigua VA Medical Center 400 Fort Hill Ave","country":{"code":"USA"}},"product_service_code":"Z1DA"},{"dates":{"posted":"2024-05-16","response_deadline":{"raw":"2024-06-21T15:00:00-04:00","utc":"2024-06-21T19:00:00Z","date":"2024-06-21","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7f12df45c9514ad0977ae0d3de59b545/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-09-28","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"7f12df45c9514ad0977ae0d3de59b545","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"943acb18c9fdfe507810ce99796c26debdde3a1506a6362381429899e6214ca4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"This page left blank intentionally","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-05-17","response_deadline":{"raw":"2024-06-28T15:00:00-04:00","utc":"2024-06-28T19:00:00Z","date":"2024-06-28","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/beb8d772f3874c43a6a17ab92e93c63c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-28","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"beb8d772f3874c43a6a17ab92e93c63c","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5f089ea2ab38be25002b4857aab4dada0db3a4a6734ed1b13185cc61335820cf","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Continuation Page Solicitation # 36C24224R0032 This amendment is to correct some errors and make additional changes. Page 1 block 10. Changed from This is a 100% Veteran Owned Small Business (VOSB) set-aside procurement TO This is a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) . The business size standard changed from $19.5M TO $19M. Page 1 block 13.a Proposal due date changed from Friday, June 21, 2024, TO Friday, June 28, 2024. The time remains unchanged. Page 7 SITE VISIT The site visit changed from Thursday, May 30, 2024, at 11:00 AM Eastern TO Thursday, June 6, 2024, at 11:00 AM Eastern. Page 15 - Evaluation Factor 2 Changed from To be evaluated favorably the offeror must provide details of three (3) previous similar contracts within the past three (3) years including : TO To be evaluated favorably the offeror must provide details of three (3) previous similar contracts within the past ten (10) years including: Note: A copy of this amendment must be included with your proposal.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-07","response_deadline":{"raw":"2024-06-28T15:00:00-04:00","utc":"2024-06-28T19:00:00Z","date":"2024-06-28","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fdcec53acdf3498fbc474f22a8e534a0/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-28","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fdcec53acdf3498fbc474f22a8e534a0","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"c0042f416dabc378f0a6a0135b02a33deda496f89d5f4479e09e546ef6e619b7","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Continuation Page Solicitation # 36C24224R0032 This amendment is issued to address RFIs. 1. Looking thru the spec sections on the VAMC Canandaigua project and we do not see the below highlighted sections. Could you please advise? VAMC Response: Refer to amended specifications attached. 2. The drawings regarding Project #528A-20-502 are 8.5 x 11.Â Will full size drawings be available? VAMC Response: Refer to amended plans attached. 3. Could you please clarify whether this amendment needs to be signed and submitted with the bid, or if simply acknowledging receipt on the SF1442 is sufficient? A. Simply acknowledging receipt on the SF1442 is sufficient. 4. Page 15 of the solicitation under Factor 2 says: The past performance section shall not exceed four (4) pages and shall be rated based on recent and relevant project submittals. To be evaluated favorably the offeror must provide details of three (3) previous similar contracts within the past three (3) years including: Does this mean (4) total pages or (4) pages per project times (3) projects equivalent to (12) pages?Â A. 4 pages per project for a total of 12 pages Is the expectation that contractors use the file named S02 Contractor Projects Form.docx to complete this task, or can the task be completed as long as all items on the Contractor Projects Form have been accounted for within the contractor s response? Yes, the task can be completed as long as all items on the Contractor s project form have been accounted for. 5. Is there a mechanical schedule that lists the boiler flue gas economizer? It s called out for in the spec but it is not listed in any schedule. VAMC Response: See schedule below. 6. What are the materials of construction for the water softener? We do not see the water softener listed in the spec I believe this should be in the missing spec section 23 50 11 boiler plant mechanical equipment. VAMC Response: This information is in specification 223111 Water Softeners. 7. 01 00 00 1.26 Submittal Hosting. Can the Contractor utilize Procore for the submittal exchange on-line interface or is the Contractor to pay for Submittal Exchange for this Contract? VAMC Response: Autodesk Construction Cloud will be used for this project and administered by the VA. Refer to spec section 01 32 00 of the amended specifications attached. Also refer to amended scope of work. 8. Please confirm the fabricator and erector must be an AISC Fabricator and Erector per 05 12 00 1.5. VAMC Response: Confirmed. 9. Specification 01 91 00 is not included. Please include. Is the CxA by the Government or the Contractor? VAMC Response: Refer to the amended specifications attached. Commissioning agent shall be a third party not part of this contract. 10. Please provide equipment schedule and basis of design for the condensate receivers and pumps. CRUs are detailed and outlined in Specification 23 22 23, but no sizing is provided on schedule. VAMC Response: See schedule below. 11. There is no Specification for 25 10 10. In general, a lot of specification sections are missing. We respectfully request that the VA go through and confirm that each specification in the TOC is included. VAMC Response: Refer to amended specifications attached. 12. Drawing A-101 on page 53 of 166 General Notes and Keyed Notes are scrambled. VAMC Response: Refer to amended plans attached. 13. Drawing A-203 on page 59 of 166 General Notes and Keyed Notes are scrambled. VAMC Response: Refer to amended plans attached. 14. Drawing MH-102 on page 107 of 166 General Notes and Keyed Notes are scrambled. VAMC Response: Refer to amended plans attached. 15. Drawing MH-103 on page 108 of 166 General Notes and Keyed Notes are scrambled. VAMC Response: Refer to amended plans attached. 16. Drawing EP-104 on page 146 of 166 General Notes and Keyed Notes are scrambled. VAMC Response: Refer to amended plans attached. 17. Is the VA responsible for providing a temporary control room/bathroom for the operators during construction? VAMC Response: A temporary control room and bathroom are not needed because the new control room and bathroom are in an area that is not currently being used. 18. Please provide a full-size PDF file for the drawings. The PDF is currently in 11 x 17. VAMC Response: Refer to amended plans attached. 19. Does the Prime Contractor need to have a full-time on-site SSHO and a full-time on-site QC Manager (in addition to the Super)? Does the Project require three on-site full-time hats, or can one individual fulfill multiple roles? VAMC Response: The SSHO can be the superintendent OR QC manager. The QC manager cannot be the superintendent. 20. SF 1442 indicates the project shall be complete within 589 calendar days after issuance of NTP, which equates to ~19.5 months. The boiler submittals will likely take 12-weeks after NTP to generate plus VA/A&E submittal review (likely another 30 days). Once approved, manufacturing lead time is likely at 26 weeks, or half a year. By the time the boilers and balance of plant equipment arrive to site, ~300 calendar days have expired. Once the system is fully installed after the equipment is set, and fully started/commissioned, the boilers must go through a 30-day runtime before entering Phase IV. 589 calendar days is not enough time to complete this Contract. We respectfully request that the Government reevaluate. VAMC Response: Revised period of performance is 730 days. Refer to the amended SOW. 21. Evaluation Factor 2 - Contractor's Past Performance states that the section shall not exceed four pages. It further states: \"This information shall be submitted for this procurement using Exhibit C, Past Performance Questionnaire, transmitted via Exhibit B, Sample Transmittal Letter and past Performance Evaluation Questionnaire.\" \"S02 - Contractor Projects Form\" and \"S02 - Past Performance Questionnaire\" were included with the solicitation package documents. Please advise on the following: Is this Factor to include both completed Project Forms and PPQs for each of the three projects submitted? See #4 above. If PPQs are required, are they to be submitted in the Factor or directly back to the Contracting Office? Include as part of the proposal. If PPQs are required and a CPARS evaluation also exists for a particular project, we respectfully request that we be allowed to submit the CPARS in lieu of the PPQ. Several of our client's main POCs have either moved to other agencies or have retired. Additionally, several of our client's main POCs have also stated that they will not complete a PPQ if a CPARS evaluation exists. A. Considering some contractors may experience problems receiving this information, we will allow you to submit the CPARs in lieu of the PPQ. Therefore, you may submit one or the other and we will accept either. If PPQs must be submitted, and we are unable to obtain one, please advise on next steps. As mentioned in question 3, it has been quite difficult obtaining completed PPQs. See 21c above. If Project Forms and PPQs and/or CPARS are to be submitted in this Factor, we respectfully request that the Government increase the page limits as four pages will not be sufficient. See #4 above. 22. Please advise if there are page limits for Evaluation Factor 3 - Contractor's Schedule. None were listed. A. No, please follow the instructions given for the contractor s schedule. I can t imagine this would be an extremely long document. 23. Evaluation Factor 4 - Volume II - Price Information asks for a \"division cost breakdown template\" on Solicitation Page 17 of 64. No such template was provided. Please provide or advise as to how the Offeror should satisfy the requirement for divisional price breakdown. A. The Divisional breakdown is something like the example below: Division 01 - General Requirements Division 02 - Site Construction Division 03 - Concrete Division 04 - Masonry Division 05 - Metals Division 06 - Wood and Plastics Division 07 - Thermal and Moisture Protection Division 08 - Door and Windows Division 09 - Finishes Division 10 - Specialties Division 11 - Equipment Division 12 - Furnishings Division 13 - Special Construction Division 14 - Conveying Systems Division 15 - Mechanical Division 16 - Electrical 24. The Bid Guarantee clause on Solicitation Page 19 of 64 states \"(c) The amount of the bid guarantee shall be 100 percent of the bid price or , whichever is less.\" Please confirm this should read \"20 percent, or 3 million, whichever is less.\" A. Yes, the amount of the bid guarantee shall be 20 percent of the bid price or $3 million, whichever is less. 25. Solicitation Page 7 of 64 states \"(e) One (1) signed Buy American Certificate\". In looking at the Buy American Certificate clause on Solicitation Pages 62 and 63 of 64, we have never had to complete this and submit it with a proposal before. Furthermore, we will not definitively know the nature of the end products used until the submittal and buy-out phase of the project, if awarded, so we do not have the information available during the bidding phase to complete items (b) and (c). Lastly, there is no signature line featured with this clause; there is nowhere to officially sign. We respectfully request that the requirement to submit this clause (completed and signed) be removed from the Solicitation. This should be a post-award item. A. The clause 52.225-2 is replaced with 52.225-10. You are not required to sign and return the anything for this clause. You are required to Buy American. 26. Page 16 of the solicitation says: This information shall be submitted for this procurement using Exhibit C, Past Performance Questionnaire, transmitted via Exhibit B, Sample Transmittal Letter and past Performance Evaluation Questionnaire. There is no Exhibit B with the bid documents that we could find.Â Typically, this exhibit provides directions to the entity completing the PPQ and explains how and when the government expects to receive returned PPQ s.Â Should the PPQ s be returned directly to the contracting officer?Â Should the PPQ s be returned to the contractor and submitted as part of Section 2, Past Performance?Â We have seen it done both ways. It should be submitted with your proposal. The form was provided but wasn t labeled Exhibit B. I have attached with that label. If the PPQ should be returned directly to the contracting officer, when is it due? It should be a part of your proposal.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-13","response_deadline":{"raw":"2024-06-28T15:00:00-04:00","utc":"2024-06-28T19:00:00Z","date":"2024-06-28","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/96152c3bf0e3450dba6af9f38c68331a/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-28","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"96152c3bf0e3450dba6af9f38c68331a","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"729777cc583a1eb686b88bf93a4343da7782c2d11ef2eb768de98bef6f14ec8d","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"1. We are requesting that the government extend the RFI due date (currently 6/13/24) and bid due date (currently 6/28/24). The release of amendment 00002 late last week included a lot of missing specifications that our team will have to read through. The RFI due date is extended to 6/18/2024 at 16:00 Eastern Standard Time. The due date for the proposal will not be extended. 2. Do we need to overnight an original Bid Bond, or if a scanned copy included in our emailed RFP submission is sufficient? No, you do not need to overnight the original Bid Bond. Please email a scanned copy to me via email. 3. Can you please post the sign-in sheet from last week s site visit? Sign in sheet attached. 4. Will the RFI deadline be extended by one week in a similar fashion to the bid walkthrough date and the bid due date? Please Advise? See #1. 5. Will this project bid date be extended? Â We are having difficulties getting qualified subcontractors to bid this project in the time frame allotted. Many have indicated that they are already extremely busy and are asking for an extension. We have a timeframe for which we must award this contract and therefore, cannot extend it anymore. Note: This amendment does not address all the questions received. This address only the administrative questions. The technical questions will be addressed in another amendment.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-14","response_deadline":{"raw":"2024-06-28T15:00:00-04:00","utc":"2024-06-28T19:00:00Z","date":"2024-06-28","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/958a14cd910f49a68ef8d2eb33f40287/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-28","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"958a14cd910f49a68ef8d2eb33f40287","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"c2e7bb4ea7017e087d2d20186a3686f86682be8dafaf871243327024fdb9b24c","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"DOCUMENT TITLE: Comment Response Matrix Â ENCORUS PROJECT NO. 21070 CLIENT PROJECT NO. 528A5-20-502 PROJECT DESCRIPTION: Design Boiler Replacement SUBMISSION: Pre-Bid RFI DATE: 6/13/2024 **Design Boiler Replacement - Canandaigua VAMC** # DWG/SPEC # Commenter Customer Comment Encorus Response VA Response Open/Closed 1 EI701 Â Per 23 09 11, paragraph 2.5 (Pg 37/69) there is one desktop computer and one, 19 monitor for the SCADA computer. However See updated 230911 paragraph 2.5 attached. See attached for 4160V Generator and CP-5 points list. Note that the CP-5 points list that contrains equipment that has been previously removed and would no longer need to be monitored. For the 480V switchgear, the SCADA system should monitor the status of each breaker within the switchgear and incoming and generator Voltage, Current, kW, kVA, PF, and kWH. The security system is stand alone, however provisions should be added to the operator stations to monitor cameras throughout and surrounding the boiler plant. The monitored points for the other equipment are shown on the PID Drawings Â Â 2 MK601 Â We do not see the receiver tank sizes in the mechanical schedule or specification. Could you please advise to the receiver tank size? We see the condensate receivers shown on drawing MK101 and see the pumps for this receiver on the MK601 schedule, but do not see any mention of tank size. A new condensate receriver schedule was provided with the previous set of RFI responses on 6/4/2024. The tank size is 65 gallons. The schedule is shown below. Â Â Â Â Â 3 Â Â In the RFI responses the Government lists two revised contract durations 730 and 750 calendar days. Can you please advise which number is correct? 750 Calendar Days Â Â 4 D-641 Â The drawing D-641 shows the blowdown separator cooling through a solenoid valve, which is controlled from panel...The drawing D-641 shows the blowdown separator cooling through a solenoid valve, which is controlled from panel CP-6A. CP-6A is the Deaerator control panel. Also shown is a temperature transmitter. 99% of the VA drawings show the self-controlling temperature regulating valve with capillary tubing. Please confirm the design intent is to have this process controlled via the PLC controlled solenoid valve for admitting cooling water to BDHR. Local control with capillary tubing is acceptable. Â Â 5 Â Â In review of D-621, 641, 642 can you please confirm that all the manual valves and other associated components for the main and pilot gas trains below will require position feedback (4-20mA) signal? Or is this a typo? The steam flow diagram D-642 has ZT position indication for all the manual valves (11 per my count) in the steam flow diagram. It s labeled as position feedback (4-20mA) signal, and not a simple switch contact (such as position either open or close limit switch). The steam silence vent valve(s) are manual. Typically, these are motorized electric modulating valves that can be controlled by master panel. This project does not appear to have this, but does have the position feedback of the manual vent valves as well. The safety relief valves are also indicating the requirements for a ZSO. We don t believe the illustrated valve exists. Please confirm if this is a typo and or specify manufacturer. The safety valves AFGSOV and APFGSOV are required to have a prove open switch, prove close switch, and a control open function. The vent valves AFGSVV and APFGSVV are required to have a prove open switch, prove close switch, and a control close function. The symbols above the pressure transmitters and flow transmitters are for the pressure and flow information, but the valves are just manual valves without any position indication or control. Manual valves on the steam header can have a close limit switch (ZIC). Although the drawing shows manual valves, a change to a motorized valve would be acceptable if desired for testing and tuning. The ZSO should not be on the safety relief valves. See specification 23 52 39 paragraph 2.2 B for requirements. Â Â 6 Â Â Drawing EI 111 details the dangerous gas detection system. Is there any technical information available for the existing system, IOM, wiring diagram, etc..? Yes, there are IOM manuals and reference drawings. One caveat is that the system was hacked up more than it was supposed to be by the company removing the biomass boilers. Reference documents are attached in case you want to post them. Â Â 7 Â Â Per the Specifications It is noted that only the Natural Gas piping system for the Mechanical and Plumbing scope is to be seismically rated. Can you confirm that this is the only required mechanical or plumbing system to require seismic bracing? Yes, the natural gas piping is the only seismically rated system. Â Â This document is also provided as an attachment.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-20","response_deadline":{"raw":"2024-07-09T15:00:00-04:00","utc":"2024-07-09T19:00:00Z","date":"2024-07-09","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9ec594bf402a4fb28916950fa68e1a70/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-08","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9ec594bf402a4fb28916950fa68e1a70","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"8123d7c3d8e499711056efb53efc191ba09e9ec9cf953c81584d46aa4d21a048","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"****This page left blank intentionally****","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-26","response_deadline":{"raw":"2024-07-09T15:00:00-04:00","utc":"2024-07-09T19:00:00Z","date":"2024-07-09","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3a0b86afca944dcebc26494aa33c6a84/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-08","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"3a0b86afca944dcebc26494aa33c6a84","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"8ef59600f9ad084dd94f3ea4344a48ac5cbc8b1b8805b9b5fa281f858fd668cd","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"BOILER REPLACEMENT PROJECT PROJECT #: 528A5-20-502 Solicitation Number: 36C24224R0032 Please confirm that all exterior UG natural gas shall be PE piping until it transitions to above ground. VAMC Response: All underground gas piping (excluding service connections to buildings) shall be PE. Refer to Specification section 23 11 23 paragraph 2.10. Please confirm what new mechanical equipment is to be used for temporary heating and cooling. VAMC Response: The new rooftop RTU units 1,2&3 may be used for temporary heating and cooling once they are installed. New unit heaters, as well as the existing makeup air units may also be used once, they are installed and piped. Manufacturer s warranty for any equipment shall begin after final acceptance, use of this equipment shall not affect the manufacturer s warranty start date. Please confirm what the number of working days to get submittals and RFI s to and from the VA is to be. VAMC Response: Per specification section 01 33 23 paragraph 1.10 VA review period is a maximum of 15 working days for submittals and a maximum of 10 working days for RFI s. Please confirm whether the VA/EOR is to provide a BIM model of the design for coordination purposes. VAMC Response: EOR can provide a design model for reference at the beginning of the project, but the coordination model is created and administrated by the contractor. Please confirm that the NYS Plumbing, Mechanical and Fuel Gas Codes are in force for this Project per 22 05 11 1.5 B 4, 23 05 10 1.5 B 4, 23 05 11 1.5 B 4 and 23 21 11 1.5 C VAMC Response: The VA is generally not beholden to local or state codes except where required to coordinate or receive utilities, services, etc., with local jurisdictions or utility companies. The contractor shall plan to perform the project based on the codes listed within the specs and drawings. This can vary, for example the VA follows the International Plumbing Code for plumbing, but NFPA 54 for Fuel Gas. Where two codes are listed the more stringent requirement is to be used of the two (as stated in the spec sections referenced). Is HDPE an acceptable alternate material in lieu of steel pipe & fittings with Coal Tar Enamel coating per spec 231123-5, 2.1, B, 1. Please advise? VAMC Response: Service connection to buildings shall be black steel pipe with coal tar enamel coating per spec. Are traditional piping portals or piping boots supplied by the Roofer an acceptable alternate to the copper flashing defined in 22 05 11 2.12 K. Please advise? VAMC Response: A traditional pipe flashing with a rubber boot is an acceptable alternative. Please confirm that the IFC design fully accommodates the Contractor to meet the requirements of 22 05 11 3.1 C and Q2 as this is not a contractor coordination responsibility. VAMC Response: The IFC design should accommodate the contractor to meet these requirements. The contractor is required to provide coordination/shop drawings. If there is an issue with accessibility to a specific device, valve, or equipment, the contractor may relocate or provide justification for its location. Can trap guards be utilized in lieu of piped trap primers listed in specification section 22 13 00, 2.8. Trap Guards are generally used as industry standard in lieu of Trap Primers. Please advise? VAMC Response: Trap guards are acceptable. Please confirm the percentage of Systems (equipment) that are required to be commissioned per specification section 01 91 00. VAMC Response: There are not large numbers of the same type of equipment therefor 100% of the equipment shall be commissioned. Quality Assurance section of 232213 states that we are to comply with provisions in ASME B 31.9 for steam and condensate heating piping. But the Execution section references B 31.1. Please confirm that all welding is to be per B31.9 requirements and no NDE will be required on these piping systems. VAMC Response: ASME B31.9 is the correct reference for steam and condensate heating piping. No NDE is expected. Specification section 233100 2.1 references various duct materials but no duct construction schedule has been provided. Please provide a Schedule for all ductwork systems on the Project. VAMC Response: The duct construction schedule is: RTU-1,2&3: SA duct +2\" WC, RA duct -1\" WC. Locker room & utility room exhaust duct: - 1\" WC. Generator ventilation ductwork +1\" WC. Per SMACNA standards all ductwork that operates at 2 WC and less does not require duct leakage testing. Specification section 233100, 3.2, B States that all ductwork requires duct leakage testing. Please confirm that duct leakage testing can be eliminated on duct that operates at 2 WC and less. VAMC Response: Duct leakage testing can be eliminated on ductwork, as referenced in the SMACNA standards for ductwork operating at less than 3\" WC. Per specification section 235239,3.3 we are to test all safety devices in accordance with the VHA Boiler Plant Safety Devices Testing Manual and all construction documents. The VHA Boiler Safety Devices Testing Manual (current version) has not been included with the construction documents. Please provide the VHA Boiler Safety Devices Testing Manual (current version) for review and adherence to. VAMC Response: Refer to Attachment A_VHA Boiler and Associated Plant Safety Device Testing Manual 8th Edition. This is also available in the TIL. Is Specification section 25 10 10 to be included as part of the temperature controls contractor scope of work? Or is this to be a separate subcontractor? VAMC Response: Remove specification section 25 10 10 from the scope. Per SMACNA any FD, or FSD that are NOT shown on the Contract Drawings are not included in the Contractors scope of work. If any FD or FSD not shown on the Contract Drawings are to be included in this contract they will need to be located on the documents. Please confirm we are not responsible for locating/inferring these devices if not shown and are to be address by the engineer of record. VAMC Response: FD/FSD's are not required. Per General note #1 on drawing M-001 we are to adhere to the VA Steam, Heating Hot Water and Outside Distribution System Manual (latest edition), but no such manual was issued with the bid. Please provide the VA Steam, Heating Hot Water and Outside Distribution System Manual (latest edition) for review and adherence to. VAMC Response: Disregard the note. This is a design manual, not a construction manual. Are Swagelok fittings an acceptable make for the Feedwater sampling and chemical feed piping on this project? Specification 232111, 2.12, B calls for Stainless steel type 316 welding fittings, but no manufacture was listed. Please advise. VAMC Response: Yes, appropriately rated Swagelok fittings are acceptable for stainless tubing. The specific types and sizes will be evaluated during the submittal phase. Expansion joints, Guides and Anchors are not specified in the Boiler Plant Piping specification. Please confirm that no expansion joint, guide or anchor is required on any piping system outlined in this specification. VAMC Response: There are no expansion joints required. Pipe flexibility inside the plant should be provided by the pipe routing or expansion loops. Requirements for pipe supports are in 232111 2.29. Devices must comply with specified MSS SP-58 type numbers. Per specification 232111 Stress analyses on the boiler plant piping systems is to be part of the design and to also be required after the systems are built. Please confirm that this stress analysis is to be completed and provided by the engineer of record. VAMC Response: The contractor is required to provide stress analysis along with the shop drawings, and then an updated stress analysis with the as-built drawings. Based on the documentation requested above and the current local market project volume. We formally request a 2-week extension for this project. VAMC Response: The bid date will not be extended. Specification section 25 10 10 1.10, Maintenance and Service, requires the Prime to provide a one (1) year preventive maintenance plan/service as part of the new Advanced Utility Metering System. Who is the current power monitoring and control system vendor responsible for the preventative maintenance on the existing system? VAMC Response: Remove specification section 25 10 10 from the scope. Specification section 25 10 10 outlines mechanical meter requirements (e.g., type, accuracy, turndown, etc.), however specification section 23 09 11 also outlines mechanical meter requirements. The two specifications are not aligned. Which specification section shall the Prime and Boiler Manufacturer follow? VAMC Response: Remove specification section 25 10 10 from the scope. Please provide as-builts of the existing Advanced Utility Metering system as outlined in specification section 25 10 10.Â It appears, if this specification section is applicable, that the Prime shall integrate with the existing system on campus. Please provide product data on the existing remote terminal units as well (manufacturer, wiring diagrams, etc.). VAMC Response: Remove division 25 from the scope. The existing system shall be demolished with the existing boiler plant. In general, on the recent VHA Boiler Plant we have both bid and constructed, the Government typically removes DIV. 25. Many VA s no longer keep up with these systems. VAMC Response: Remove division 25 from the scope. Per 23 09 11, paragraph 2.5 (Pg 37/69) there is one desktop computer and one, 19 monitor for the SCADA computer. However, per drawing E-201, an equipment rack w/ server is shown and a desk with client desktops and two, 60 monitors and 8 desktop monitors. What is specified in 23 09 11 and what is shown in drawing E-201, E-401, and EI701 are not even close to agreement, and totally contradict. Drawing E-401 is a plan view of the same equipment in the control room, and this drawing confirms what is shown in E-201. VAMC Response: Refer to attachment B for updated 230911 paragraph 2.5. See attached for 4160V Generator and CP-5 points list. Note that the CP-5 points list that contains equipment that has been previously removed and would no longer need to be monitored. For the 480V switchgear, the SCADA system should monitor the status of each breaker within the switchgear and incoming and generator Voltage, Current, kW, kVA, PF, and kWH. The security system is stand alone; however, provisions should be added to the operator stations to monitor cameras throughout and surrounding the boiler plant. The monitored points for the other equipment are shown on the PID Drawings. There appears to be some confusion amongst the trades as it was stated at the pre-bid site visit that an amendment would be released that indicates the project requires a new generator in lieu of relocating the existing generator. Is that change not going to occur during the bid phase? We have not seen the revised drawings and revised specifications. VAMC Response: Bid work as shown on the current contract plans to relocate the existing generator. Any potential changes to the generator will be handled post award.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-27","response_deadline":{"raw":"2024-07-09T15:00:00-04:00","utc":"2024-07-09T19:00:00Z","date":"2024-07-09","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fef6ddfba41b42849b66faaf3338de11/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-08","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fef6ddfba41b42849b66faaf3338de11","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"d7734a70af28c6977dfeb28b90d19a09048d006f9a1789ac41a71fc1934d0ac1","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"BOILER REPLACEMENT PROJECT PROJECT #: 528A5-20-502 Solicitation Number: 36C24224R0032 This amendment is issued to provide clarification for question 11 from the previous amendment. Q. Quality Assurance section of 232213 states that we are to comply with provisions in ASME B 31.9 for steam and condensate heating piping. But the Execution section references B 31.1. Please confirm that all welding is to be per B31.9 requirements and no NDE will be required on these piping systems. This answer was provided in the previous amendment for this question: Â VAMC Response: ASME B31.9 is the correct reference for steam and condensate heating piping.Â No NDE is expected. ASME B31.1 is the standard. Section 23 21 11 indicates the entire installation shall comply with ASME B31.1 and appendices. ASME B31.1 is outlined (24) times in the specifications. Furthermore, NDE is required pursuant to SECTION 23 21 11 3.3-H and SECTION 23 22 13 3.3-H. ASME B31.9 Code for Pressure Piping is for Plants which do not generate steam over 15psig (this comes directly out of the VHA design manual). Clarification Response below: Â Â Â A.Â Â Â Â B31.9 applies to 23 22 13 and B31.1 applies to 23 21 11 .","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-06-28","response_deadline":{"raw":"2024-07-09T15:00:00-04:00","utc":"2024-07-09T19:00:00Z","date":"2024-07-09","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/82b3e955e7df4859885d83c62fd3665c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-08","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"82b3e955e7df4859885d83c62fd3665c","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"bf031f8fe9fde5cf4b7d773ba0a65534eb7b2fa89c5fd96b7a8fcdb0e1980306","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"BOILER REPLACEMENT PROJECT PROJECT #: 528A5-20-502 Solicitation Number: 36C24224R0032 This amendment is to correct page 5 paragraph (e) from: (e) VAAR Clause 852-219-77 (included herein) is required to be completed and returned with each proposal. Proposals without a completed VAAR Clause 852.219-77 will be considered ineligible for evaluation and award. TO (e) VAAR Clause 852-219-75 (included herein) is required to be completed and returned with each proposal. Proposals without a completed VAAR Clause 852.219-75 will be considered ineligible for evaluation and award.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"dates":{"posted":"2024-07-02","response_deadline":{"raw":"2024-07-09T15:00:00-04:00","utc":"2024-07-09T19:00:00Z","date":"2024-07-09","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/95335920282d46ecae605612639df0e5/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-08","archive_type":"auto_custom"},"contacts":[{"name":"Veronica J Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"95335920282d46ecae605612639df0e5","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"a209623b5db062a873764818684ebd970ef38dfd28a1af4eba396d68045d2c63","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"This page is left blank intentionally.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"},{"award":{"date":"2024-09-27","amount":"21627110.00","number":"36C24224C0131","awardee":{"raw":"SERVIAM CONSTRUCTION LLC ALTOONA 16601","name":"SERVIAM CONSTRUCTION LLC ALTOONA 16601"}},"dates":{"posted":"2024-09-27","award_date":"2024-09-27"},"links":{"sam":"https://sam.gov/workspace/contract/opp/9f58c4250c52443789802e6da0780d4b/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z1DA--528A5-20-502 BOILER REPLACEMENT PROJECT","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-01-04","archive_type":"auto_custom"},"contacts":[{"name":"Veronica Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","phone":"716-862-7461 ext. 22443","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"9f58c4250c52443789802e6da0780d4b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"78718c20a3f42df731586e3c0a478d5ddad3fa7865f6c8b04c0821241668c71a","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24224R0032","product_service_code":"Z1DA"}],"due_at":"2024-07-09T19:00:00Z","due_date":"2024-07-09","closes_at":"2024-07-09T19:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36069","county_name":"Ontario County","city":"3612144","city_name":"Canandaigua","country":"USA","winner_key":"XCHST6L53NH6","amount":"21627110.00","linked_awards":12,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"95335920282d46ecae605612639df0e5","description":{"text":"This page is left blank intentionally.","html":null,"origin":"extract"},"contacts":[{"name":"Veronica Baldwin","role":"primary","email":"Veronica.Baldwin1@va.gov","phone":"716-862-7461 ext. 22443","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_36C24224C0131_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24224C0131_3600_-NONE-_-NONE-/","piid":"36C24224C0131","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"XCHST6L53NH6","recipient_name":"SERVIAM CONSTRUCTION LLC","recipient_uei":"XCHST6L53NH6","recipient_cage":"6Q0H0","recipient_city":"ALTOONA","recipient_state":"PA","sub_name":"Department of Veterans Affairs","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","office_key":"o-36C242","first_action_date":"2024-09-27","last_action_date":"2026-09-11","actions":7,"obligated":"22612581.74","current_total_value":"22612581.74","potential_total_value":"22612581.74","naics":"238220","psc":"Z1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":3,"description":"REPLACE BOILERS CANANDAIGUA VA MEDICAL CENTER","method":"piid","confidence":"high","evidence":["award number 36C24224C0131 equals the contract number","same awarding office 36C242"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24226Q0719","latest_notice_id":"e0e915a1f5c54ed3a9fe37d7e91513ce","title":"Y1DA--Supply and Install Welded Sheet Flooring","solicitation_number":"36C24226Q0719","notice_type":"k","first_type":"k","first_posted":"2026-08-27","last_posted":"2026-08-27","notices":3,"due_at":"2026-09-25T15:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T15:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238330","psc":"Y1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C24226Q0994","latest_notice_id":"969fc8efb75b4ffdb8fa274bbf1f43d7","title":"R499--FY26 Lifeguard and Pool Maintenance Services (B+ OPT)","solicitation_number":"36C24226Q0994","notice_type":"p","first_type":"o","first_posted":"2026-09-16","last_posted":"2026-09-16","notices":2,"due_at":"2026-09-25T16:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"561210","psc":"R499","set_aside":"SBA","state":"NY","county":"36005","county_name":"Bronx County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"36C24226Q0990","latest_notice_id":"ed118569f5f043afa126ed9ae906501a","title":"J059--FY26 Uninterrupted Power Source Maintenance EO and Lyons VAMC (B=OPT4)","solicitation_number":"36C24226Q0990","notice_type":"o","first_type":"p","first_posted":"2026-09-16","last_posted":"2026-09-16","notices":2,"due_at":"2026-09-25T16:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T16:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"811310","psc":"J059","set_aside":"SDVOSBC","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-21T04:10:25.213403Z"},{"key":"36C24226R0097","latest_notice_id":"40d039920c5a4317840896604e9857b5","title":"J039--561A4-25-500 Elevator Upgrade & Modernization Repairs at VA NJ HCS Lyons Buildings 6 & 53","solicitation_number":"36C24226R0097","notice_type":"k","first_type":"k","first_posted":"2026-08-10","last_posted":"2026-09-18","notices":7,"due_at":"2026-09-28T15:00:00Z","due_date":"2026-09-28","closes_at":"2026-09-28T15:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238290","psc":"J039","set_aside":"SDVOSBC","state":"NJ","county":"34035","county_name":"Somerset County","city":"3442180","city_name":"Lyons","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-19T03:47:35.784222Z"},{"key":"36C24226Q08530","latest_notice_id":"95422ee5c91b4b6583cc677b444929f3","title":"Y1DA--Drop Ceiling Demo, Disinfect and Replace at the Brooklyn VA Medical Center","solicitation_number":"36C24226Q0853_0","notice_type":"k","first_type":"k","first_posted":"2026-08-28","last_posted":"2026-09-14","notices":2,"due_at":"2026-09-29T20:00:00Z","due_date":"2026-09-29","closes_at":"2026-09-29T20:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":"36047","county_name":"Kings County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}