{"canonical":"https://abierto.us/opportunities/36c10x27q0004","key":"36C10X27Q0004","url":"https://abierto.us/opportunities/36c10x27q0004","title":"6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)","solicitation_number":"36C10X27Q0004","notice_type":"r","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-10-19T16:00:00Z","first_posted":"2026-10-02","last_posted":"2026-10-02","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"f2656d8f52574a45982c827c030317f5","title":"6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)","solicitation_number":"36C10X27Q0004","notice_type":"r","base_type":"r","posted":"2026-10-02","posted_at":"2026-10-02T13:17:26.629Z","due_at":"2026-10-19T16:00:00Z","due_date":"2026-10-19","cancelled":false,"archived":false,"archive_date":"2026-12-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f2656d8f52574a45982c827c030317f5/view","enriched":true,"history":[{"index":1,"title":"6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-02T13:17:26.629Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2656d8f52574a45982c827c030317f5","solicitation_number":"36C10X27Q0004"}]}],"latest_notice_id":"f2656d8f52574a45982c827c030317f5","first_type":"r","notices":[{"dates":{"posted":"2026-10-02","posted_at":"2026-10-02T13:17:26.629Z","created_at":"2026-10-02T13:17:24.416Z","modified_at":"2026-10-02T13:17:26.629Z","response_deadline":{"raw":"2026-10-19T12:00:00-04:00","utc":"2026-10-19T16:00:00Z","date":"2026-10-19","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f2656d8f52574a45982c827c030317f5/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)","agency":{"office":{"code":"36C10X","name":"SAC FREDERICK (36C10X)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-18","archive_type":"auto_custom"},"history":[{"index":1,"title":"6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-02T13:17:26.629Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2656d8f52574a45982c827c030317f5","solicitation_number":"36C10X27Q0004"}],"contacts":[{"name":"Alanna Wilson","role":"primary","email":"Alanna.Wilson@va.gov","phone":"240-215-1633","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"f2656d8f52574a45982c827c030317f5","lineage_id":"f2656d8f52574a45982c827c030317f5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T04:17:37.513298783Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"02e781982c5c3aad4d35c40774f413d2-26\"","fetched_at":"2026-10-04T04:15:09.916447409Z","row_sha256":"8b1de5e97b88fabd8f2cd8a9e1cde7b5ed94671fbfbe4a348ad059d9fbc6bb72","last_modified":"2026-10-04T03:30:39Z"},"updated_at":"2026-10-04T04:15:09.916447409Z","first_seen_at":"2026-10-03T03:46:48.862698055Z"},"description":{"html":"1.0 DESCRIPTION\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs  (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable. \nThe EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal FujifilmÂ® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States. \nThe associated North American Industry Classification System (NAICS) code for this procurement is 334510   Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. \nThe FAR Provision found at 52.204-7 requires that  The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation.  You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission.\nSubmissions for this  Sources Sought Notice  shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: \nAlanna.Wilson@va.gov\nAnthony.Zibolski@va.gov\nEmail responses shall include the following subject line:  Response to Sources Sought Notice 36C10X27Q0004. \nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.\n2.0 SCOPE OF WORK\nScanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations.\n\nThe following Contract Line Items (CLINs) are being considered:\nContract Line Items\nManufacture\nPart Number\nDescription\n0001\nSonosite\nL22916 \nTransducer, L12-3\n0002\nSonosite\nL23117 \nTransducer, C10-3\n0003\nSonosite\nL23119 \nTransducer, C5-1\n0004\nSonosite\nL23120 \nTransducer, L15-4\n0005\nSonosite\nL23121  \nTransducer, IC10-3\n0006\nSonosite\nL23972 \nTransducer, L19-5\n0007\nSonosite\nL24087  \nTransducer, P5-1\n0008\nSonosite\nL25100 \nSonosite PX Ultrasound System\n0009\nSonosite\nL25110 \nSonosite PX Stand\n0010\nSonosite\nL25200 \nPrinter, B and W Hybrid Graphic, SONY UP-X898MD\n0011\nSonosite\nL27766 \nT8-3 ULT-2020 Ultrasound Leakage Tester Kit\n0012\nSonosite\nL28354\nSonosite LX Ultrasound System\n0013\nSonosite\nL29076 \nSonosite ECG Module\n0014\nSonosite\nL29465 \nTransducer, T8-3\n12 Months - Standard Coverage Warranty\n0015\nSonosite\nL29671 \nTransducer, P11-3\n0016\nSonosite\nL30229 \nTransducer, T8-3 POCUS Bundle\n-12 Months - Standard Coverage Warranty\n0017\nSonosite\nL30257 \nTransducer, L13-6\n0018\nSonosite\nL31500 \nSonosite ST Ultrasound System\n0019\nSonosite\nL33270 \nTransducer, UHF46-20 MHz Ultra High-Frequency\n-12 Months - Standard Coverage Warranty\n0020\nSonosite\nP31199 \nSteep Needle Profiling, Sonosite ST\n0021\nSonosite\nP31440\nSonosite Voice Assist\n-12 Months - Standard Coverage Warranty\n0022\nSonosite\nP31987 \nSmall Basket\n0023\nSonosite\nP31988 \nLarge Basket\n0024\nSonosite\nP32357 - Sonosite PIV Assist\nSonosite PIV Assist\n0025\nSonosite\nP32441-SVCCON \nPoint of Sale Warranty Plus (2 years), PX System\n0026\nSonosite\nP32442-SVCCON \nPoint of Sale Warranty Plus (2 years), LX System\n0027\nSonosite\nP32443-SVCCON \nPoint of Sale Warranty Plus (2 years), ST System\n0028\nSonosite\nP32444-SVCCON \nPoint of Sale Warranty Plus (2 years), PX/LX/ST/MT\nTransducers (Not applicable for the T8-3 or UHF46x Transducers)\n0029\nSonosite\nSonosite Institute for Point-of-Care Ultrasound\nExclusive access to\nover 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone.  (Included)\n\nRespondents should identify a complete solution including associated accessories, as required for full functionality.\n\nThe following Salient Characteristics (SCs) are being considered:\nCLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9\nCLINs 0014, 0016, 0019, 0021 apply to the following SC 10 \nCLINs 0026-0028 apply to the following SC 12\nCLIN 0029 applies to the following SC 11\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMultiple configurations of the devices\nLiterature Review\nSC 2\nMust have High-quality image resolution1280 x 1024 pixels or higher\nLiterature Review\nSC 3\nMust have multiple Doppler modes to include color, and continuous Wave\nLiterature Review\nSC 4\nMust have 120V and Battery powered capability \nLiterature Review\nSC 5\nMust have a Phased Array Probe with a low frequency range of between 1-5 MHz \nLiterature Review\nSC 6 \nMust have Endocavitary Probe with a frequency range between 2-12.5 MHz \nLiterature Review\nSC 7 \nMust have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe \nLiterature Review\nSC 8\nMust have Linear Probe with a frequency range greater than 12 MHz\nLiterature Review\nSC 9\nMust have needle visualization enhancement\nLiterature Review\nSC 10\nMust have a minimum one-year warranty\nLiterature Review\nSC 11\nMust provide Operator training\nLiterature Review\nSC 12\nMust provide Extended Service and Support plan\nLiterature Review\nSC 13\nMust be FDA approved\nFDA Letter\nSC 14\nMust have Intraoperative system capable of interfacing with VA Electronic Health Record System\nLiterature Review\n\nFor each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above. \nThe Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.\nIn addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors:\nSafety\nThe device will be assessed for patient safety features, including, but not limited to, the following areas: \nInfection control\nThermal injuries\nProbe maintenance \nBattery failure procedures \n\nDesign \nDesign features and functions of the offered device will be evaluated. Areas include but are not limited to the following: \nDurability of the system and the probes \nDisplay screens usability\nBarcode software to ID patients and physicians\nLow-Profile wheelbase to assist getting closer to patient\nCordless charging station\nNumber of Transducer ports \nSimplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use)\n\nPerformance \nThe device will be evaluated for its ability to perform its intended function. Areas include but are not limited to: \nCapabilities to support multiple medical services \nBatter run time\nProvided Installation \nNeedle guidance system\n\nQuality/Construction/Training \nExtended Warranty \nTraining \nSecure Data encryption HIPPAA/GDPR compliant\nMeets ANSI/AAMI ES6061 Electromechanical safety standards\n\n\n\nResponses to this Sources Sought Notice shall include the following:\n\nFull name and address of company.\nSAM Unique Entity Identifier (UEI).\nBusiness Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).\nManufacturer or Distributor:\nIf distributor, provide the full name, business size and address of the manufacturer. \nIf distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. \nCountry of Origin designation for all products proposed.\nDescribe the firm s ability to provide uninterrupted supply of products on a national scale.\nTechnical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met. \nDoes respondent offer an annual service plan, Yes or No? \nIf Yes:\nDescribe what the plan covers?\nIdentify whether the plan covers software updates, parts repair/replacement, or both\nProvide literature or other documentation describing the service plan.\nIdentify whether service is provided by the OEM or a subcontractor.\n\nIdentify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number.\nItem pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. \nNOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.\nDoes your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.\nIdentify any federal contract vehicles held by your firm through which your firm can provide this equipment. \nAre there any further standards or criteria VA should consider in a procurement action for this equipment?\nAre the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.\nAny additional information the Government should know prior to issuing a solicitation.\n Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.","text":"1.0 DESCRIPTION\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable.\nThe EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal FujifilmÂ® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States.\nThe associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees.\nThe FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission.\nSubmissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses:\nAlanna.Wilson@va.gov\nAnthony.Zibolski@va.gov\nEmail responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.\n2.0 SCOPE OF WORK\nScanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations.\n\nThe following Contract Line Items (CLINs) are being considered:\nContract Line Items\nManufacture\nPart Number\nDescription\n0001\nSonosite\nL22916\nTransducer, L12-3\n0002\nSonosite\nL23117\nTransducer, C10-3\n0003\nSonosite\nL23119\nTransducer, C5-1\n0004\nSonosite\nL23120\nTransducer, L15-4\n0005\nSonosite\nL23121\nTransducer, IC10-3\n0006\nSonosite\nL23972\nTransducer, L19-5\n0007\nSonosite\nL24087\nTransducer, P5-1\n0008\nSonosite\nL25100\nSonosite PX Ultrasound System\n0009\nSonosite\nL25110\nSonosite PX Stand\n0010\nSonosite\nL25200\nPrinter, B and W Hybrid Graphic, SONY UP-X898MD\n0011\nSonosite\nL27766\nT8-3 ULT-2020 Ultrasound Leakage Tester Kit\n0012\nSonosite\nL28354\nSonosite LX Ultrasound System\n0013\nSonosite\nL29076\nSonosite ECG Module\n0014\nSonosite\nL29465\nTransducer, T8-3\n12 Months - Standard Coverage Warranty\n0015\nSonosite\nL29671\nTransducer, P11-3\n0016\nSonosite\nL30229\nTransducer, T8-3 POCUS Bundle\n-12 Months - Standard Coverage Warranty\n0017\nSonosite\nL30257\nTransducer, L13-6\n0018\nSonosite\nL31500\nSonosite ST Ultrasound System\n0019\nSonosite\nL33270\nTransducer, UHF46-20 MHz Ultra High-Frequency\n-12 Months - Standard Coverage Warranty\n0020\nSonosite\nP31199\nSteep Needle Profiling, Sonosite ST\n0021\nSonosite\nP31440\nSonosite Voice Assist\n-12 Months - Standard Coverage Warranty\n0022\nSonosite\nP31987\nSmall Basket\n0023\nSonosite\nP31988\nLarge Basket\n0024\nSonosite\nP32357 - Sonosite PIV Assist\nSonosite PIV Assist\n0025\nSonosite\nP32441-SVCCON\nPoint of Sale Warranty Plus (2 years), PX System\n0026\nSonosite\nP32442-SVCCON\nPoint of Sale Warranty Plus (2 years), LX System\n0027\nSonosite\nP32443-SVCCON\nPoint of Sale Warranty Plus (2 years), ST System\n0028\nSonosite\nP32444-SVCCON\nPoint of Sale Warranty Plus (2 years), PX/LX/ST/MT\nTransducers (Not applicable for the T8-3 or UHF46x Transducers)\n0029\nSonosite\nSonosite Institute for Point-of-Care Ultrasound\nExclusive access to\nover 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included)\n\nRespondents should identify a complete solution including associated accessories, as required for full functionality.\n\nThe following Salient Characteristics (SCs) are being considered:\nCLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9\nCLINs 0014, 0016, 0019, 0021 apply to the following SC 10\nCLINs 0026-0028 apply to the following SC 12\nCLIN 0029 applies to the following SC 11\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMultiple configurations of the devices\nLiterature Review\nSC 2\nMust have High-quality image resolution1280 x 1024 pixels or higher\nLiterature Review\nSC 3\nMust have multiple Doppler modes to include color, and continuous Wave\nLiterature Review\nSC 4\nMust have 120V and Battery powered capability\nLiterature Review\nSC 5\nMust have a Phased Array Probe with a low frequency range of between 1-5 MHz\nLiterature Review\nSC 6\nMust have Endocavitary Probe with a frequency range between 2-12.5 MHz\nLiterature Review\nSC 7\nMust have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe\nLiterature Review\nSC 8\nMust have Linear Probe with a frequency range greater than 12 MHz\nLiterature Review\nSC 9\nMust have needle visualization enhancement\nLiterature Review\nSC 10\nMust have a minimum one-year warranty\nLiterature Review\nSC 11\nMust provide Operator training\nLiterature Review\nSC 12\nMust provide Extended Service and Support plan\nLiterature Review\nSC 13\nMust be FDA approved\nFDA Letter\nSC 14\nMust have Intraoperative system capable of interfacing with VA Electronic Health Record System\nLiterature Review\n\nFor each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above.\nThe Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.\nIn addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors:\nSafety\nThe device will be assessed for patient safety features, including, but not limited to, the following areas:\nInfection control\nThermal injuries\nProbe maintenance\nBattery failure procedures\n\nDesign\nDesign features and functions of the offered device will be evaluated. Areas include but are not limited to the following:\nDurability of the system and the probes\nDisplay screens usability\nBarcode software to ID patients and physicians\nLow-Profile wheelbase to assist getting closer to patient\nCordless charging station\nNumber of Transducer ports\nSimplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use)\n\nPerformance\nThe device will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\nCapabilities to support multiple medical services\nBatter run time\nProvided Installation\nNeedle guidance system\n\nQuality/Construction/Training\nExtended Warranty\nTraining\nSecure Data encryption HIPPAA/GDPR compliant\nMeets ANSI/AAMI ES6061 Electromechanical safety standards\n\nResponses to this Sources Sought Notice shall include the following:\n\nFull name and address of company.\nSAM Unique Entity Identifier (UEI).\nBusiness Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).\nManufacturer or Distributor:\nIf distributor, provide the full name, business size and address of the manufacturer.\nIf distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM.\nCountry of Origin designation for all products proposed.\nDescribe the firm s ability to provide uninterrupted supply of products on a national scale.\nTechnical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met.\nDoes respondent offer an annual service plan, Yes or No?\nIf Yes:\nDescribe what the plan covers?\nIdentify whether the plan covers software updates, parts repair/replacement, or both\nProvide literature or other documentation describing the service plan.\nIdentify whether service is provided by the OEM or a subcontractor.\n\nIdentify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number.\nItem pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any.\nNOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.\nDoes your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.\nIdentify any federal contract vehicles held by your firm through which your firm can provide this equipment.\nAre there any further standards or criteria VA should consider in a procurement action for this equipment?\nAre the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.\nAny additional information the Government should know prior to issuing a solicitation.\nDescribe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10X27Q0004","place_of_performance":{"street":"Nationwide"},"product_service_code":"6515"}],"due_at":"2026-10-19T16:00:00Z","due_date":"2026-10-19","closes_at":"2026-10-19T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-03T03:55:19.037358Z","principal_notice_id":"f2656d8f52574a45982c827c030317f5","description":{"text":"1.0 DESCRIPTION\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable.\nThe EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal FujifilmÂ® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States.\nThe associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees.\nThe FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission.\nSubmissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses:\nAlanna.Wilson@va.gov\nAnthony.Zibolski@va.gov\nEmail responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.\n2.0 SCOPE OF WORK\nScanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations.\n\nThe following Contract Line Items (CLINs) are being considered:\nContract Line Items\nManufacture\nPart Number\nDescription\n0001\nSonosite\nL22916\nTransducer, L12-3\n0002\nSonosite\nL23117\nTransducer, C10-3\n0003\nSonosite\nL23119\nTransducer, C5-1\n0004\nSonosite\nL23120\nTransducer, L15-4\n0005\nSonosite\nL23121\nTransducer, IC10-3\n0006\nSonosite\nL23972\nTransducer, L19-5\n0007\nSonosite\nL24087\nTransducer, P5-1\n0008\nSonosite\nL25100\nSonosite PX Ultrasound System\n0009\nSonosite\nL25110\nSonosite PX Stand\n0010\nSonosite\nL25200\nPrinter, B and W Hybrid Graphic, SONY UP-X898MD\n0011\nSonosite\nL27766\nT8-3 ULT-2020 Ultrasound Leakage Tester Kit\n0012\nSonosite\nL28354\nSonosite LX Ultrasound System\n0013\nSonosite\nL29076\nSonosite ECG Module\n0014\nSonosite\nL29465\nTransducer, T8-3\n12 Months - Standard Coverage Warranty\n0015\nSonosite\nL29671\nTransducer, P11-3\n0016\nSonosite\nL30229\nTransducer, T8-3 POCUS Bundle\n-12 Months - Standard Coverage Warranty\n0017\nSonosite\nL30257\nTransducer, L13-6\n0018\nSonosite\nL31500\nSonosite ST Ultrasound System\n0019\nSonosite\nL33270\nTransducer, UHF46-20 MHz Ultra High-Frequency\n-12 Months - Standard Coverage Warranty\n0020\nSonosite\nP31199\nSteep Needle Profiling, Sonosite ST\n0021\nSonosite\nP31440\nSonosite Voice Assist\n-12 Months - Standard Coverage Warranty\n0022\nSonosite\nP31987\nSmall Basket\n0023\nSonosite\nP31988\nLarge Basket\n0024\nSonosite\nP32357 - Sonosite PIV Assist\nSonosite PIV Assist\n0025\nSonosite\nP32441-SVCCON\nPoint of Sale Warranty Plus (2 years), PX System\n0026\nSonosite\nP32442-SVCCON\nPoint of Sale Warranty Plus (2 years), LX System\n0027\nSonosite\nP32443-SVCCON\nPoint of Sale Warranty Plus (2 years), ST System\n0028\nSonosite\nP32444-SVCCON\nPoint of Sale Warranty Plus (2 years), PX/LX/ST/MT\nTransducers (Not applicable for the T8-3 or UHF46x Transducers)\n0029\nSonosite\nSonosite Institute for Point-of-Care Ultrasound\nExclusive access to\nover 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included)\n\nRespondents should identify a complete solution including associated accessories, as required for full functionality.\n\nThe following Salient Characteristics (SCs) are being considered:\nCLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9\nCLINs 0014, 0016, 0019, 0021 apply to the following SC 10\nCLINs 0026-0028 apply to the following SC 12\nCLIN 0029 applies to the following SC 11\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMultiple configurations of the devices\nLiterature Review\nSC 2\nMust have High-quality image resolution1280 x 1024 pixels or higher\nLiterature Review\nSC 3\nMust have multiple Doppler modes to include color, and continuous Wave\nLiterature Review\nSC 4\nMust have 120V and Battery powered capability\nLiterature Review\nSC 5\nMust have a Phased Array Probe with a low frequency range of between 1-5 MHz\nLiterature Review\nSC 6\nMust have Endocavitary Probe with a frequency range between 2-12.5 MHz\nLiterature Review\nSC 7\nMust have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe\nLiterature Review\nSC 8\nMust have Linear Probe with a frequency range greater than 12 MHz\nLiterature Review\nSC 9\nMust have needle visualization enhancement\nLiterature Review\nSC 10\nMust have a minimum one-year warranty\nLiterature Review\nSC 11\nMust provide Operator training\nLiterature Review\nSC 12\nMust provide Extended Service and Support plan\nLiterature Review\nSC 13\nMust be FDA approved\nFDA Letter\nSC 14\nMust have Intraoperative system capable of interfacing with VA Electronic Health Record System\nLiterature Review\n\nFor each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above.\nThe Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.\nIn addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors:\nSafety\nThe device will be assessed for patient safety features, including, but not limited to, the following areas:\nInfection control\nThermal injuries\nProbe maintenance\nBattery failure procedures\n\nDesign\nDesign features and functions of the offered device will be evaluated. Areas include but are not limited to the following:\nDurability of the system and the probes\nDisplay screens usability\nBarcode software to ID patients and physicians\nLow-Profile wheelbase to assist getting closer to patient\nCordless charging station\nNumber of Transducer ports\nSimplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use)\n\nPerformance\nThe device will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\nCapabilities to support multiple medical services\nBatter run time\nProvided Installation\nNeedle guidance system\n\nQuality/Construction/Training\nExtended Warranty\nTraining\nSecure Data encryption HIPPAA/GDPR compliant\nMeets ANSI/AAMI ES6061 Electromechanical safety standards\n\nResponses to this Sources Sought Notice shall include the following:\n\nFull name and address of company.\nSAM Unique Entity Identifier (UEI).\nBusiness Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).\nManufacturer or Distributor:\nIf distributor, provide the full name, business size and address of the manufacturer.\nIf distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM.\nCountry of Origin designation for all products proposed.\nDescribe the firm s ability to provide uninterrupted supply of products on a national scale.\nTechnical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met.\nDoes respondent offer an annual service plan, Yes or No?\nIf Yes:\nDescribe what the plan covers?\nIdentify whether the plan covers software updates, parts repair/replacement, or both\nProvide literature or other documentation describing the service plan.\nIdentify whether service is provided by the OEM or a subcontractor.\n\nIdentify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number.\nItem pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any.\nNOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.\nDoes your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.\nIdentify any federal contract vehicles held by your firm through which your firm can provide this equipment.\nAre there any further standards or criteria VA should consider in a procurement action for this equipment?\nAre the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.\nAny additional information the Government should know prior to issuing a solicitation.\nDescribe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.","html":"1.0 DESCRIPTION\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs  (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable. \nThe EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal FujifilmÂ® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States. \nThe associated North American Industry Classification System (NAICS) code for this procurement is 334510   Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. \nThe FAR Provision found at 52.204-7 requires that  The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation.  You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission.\nSubmissions for this  Sources Sought Notice  shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: \nAlanna.Wilson@va.gov\nAnthony.Zibolski@va.gov\nEmail responses shall include the following subject line:  Response to Sources Sought Notice 36C10X27Q0004. \nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.\n2.0 SCOPE OF WORK\nScanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations.\n\nThe following Contract Line Items (CLINs) are being considered:\nContract Line Items\nManufacture\nPart Number\nDescription\n0001\nSonosite\nL22916 \nTransducer, L12-3\n0002\nSonosite\nL23117 \nTransducer, C10-3\n0003\nSonosite\nL23119 \nTransducer, C5-1\n0004\nSonosite\nL23120 \nTransducer, L15-4\n0005\nSonosite\nL23121  \nTransducer, IC10-3\n0006\nSonosite\nL23972 \nTransducer, L19-5\n0007\nSonosite\nL24087  \nTransducer, P5-1\n0008\nSonosite\nL25100 \nSonosite PX Ultrasound System\n0009\nSonosite\nL25110 \nSonosite PX Stand\n0010\nSonosite\nL25200 \nPrinter, B and W Hybrid Graphic, SONY UP-X898MD\n0011\nSonosite\nL27766 \nT8-3 ULT-2020 Ultrasound Leakage Tester Kit\n0012\nSonosite\nL28354\nSonosite LX Ultrasound System\n0013\nSonosite\nL29076 \nSonosite ECG Module\n0014\nSonosite\nL29465 \nTransducer, T8-3\n12 Months - Standard Coverage Warranty\n0015\nSonosite\nL29671 \nTransducer, P11-3\n0016\nSonosite\nL30229 \nTransducer, T8-3 POCUS Bundle\n-12 Months - Standard Coverage Warranty\n0017\nSonosite\nL30257 \nTransducer, L13-6\n0018\nSonosite\nL31500 \nSonosite ST Ultrasound System\n0019\nSonosite\nL33270 \nTransducer, UHF46-20 MHz Ultra High-Frequency\n-12 Months - Standard Coverage Warranty\n0020\nSonosite\nP31199 \nSteep Needle Profiling, Sonosite ST\n0021\nSonosite\nP31440\nSonosite Voice Assist\n-12 Months - Standard Coverage Warranty\n0022\nSonosite\nP31987 \nSmall Basket\n0023\nSonosite\nP31988 \nLarge Basket\n0024\nSonosite\nP32357 - Sonosite PIV Assist\nSonosite PIV Assist\n0025\nSonosite\nP32441-SVCCON \nPoint of Sale Warranty Plus (2 years), PX System\n0026\nSonosite\nP32442-SVCCON \nPoint of Sale Warranty Plus (2 years), LX System\n0027\nSonosite\nP32443-SVCCON \nPoint of Sale Warranty Plus (2 years), ST System\n0028\nSonosite\nP32444-SVCCON \nPoint of Sale Warranty Plus (2 years), PX/LX/ST/MT\nTransducers (Not applicable for the T8-3 or UHF46x Transducers)\n0029\nSonosite\nSonosite Institute for Point-of-Care Ultrasound\nExclusive access to\nover 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone.  (Included)\n\nRespondents should identify a complete solution including associated accessories, as required for full functionality.\n\nThe following Salient Characteristics (SCs) are being considered:\nCLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9\nCLINs 0014, 0016, 0019, 0021 apply to the following SC 10 \nCLINs 0026-0028 apply to the following SC 12\nCLIN 0029 applies to the following SC 11\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMultiple configurations of the devices\nLiterature Review\nSC 2\nMust have High-quality image resolution1280 x 1024 pixels or higher\nLiterature Review\nSC 3\nMust have multiple Doppler modes to include color, and continuous Wave\nLiterature Review\nSC 4\nMust have 120V and Battery powered capability \nLiterature Review\nSC 5\nMust have a Phased Array Probe with a low frequency range of between 1-5 MHz \nLiterature Review\nSC 6 \nMust have Endocavitary Probe with a frequency range between 2-12.5 MHz \nLiterature Review\nSC 7 \nMust have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe \nLiterature Review\nSC 8\nMust have Linear Probe with a frequency range greater than 12 MHz\nLiterature Review\nSC 9\nMust have needle visualization enhancement\nLiterature Review\nSC 10\nMust have a minimum one-year warranty\nLiterature Review\nSC 11\nMust provide Operator training\nLiterature Review\nSC 12\nMust provide Extended Service and Support plan\nLiterature Review\nSC 13\nMust be FDA approved\nFDA Letter\nSC 14\nMust have Intraoperative system capable of interfacing with VA Electronic Health Record System\nLiterature Review\n\nFor each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above. \nThe Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.\nIn addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors:\nSafety\nThe device will be assessed for patient safety features, including, but not limited to, the following areas: \nInfection control\nThermal injuries\nProbe maintenance \nBattery failure procedures \n\nDesign \nDesign features and functions of the offered device will be evaluated. Areas include but are not limited to the following: \nDurability of the system and the probes \nDisplay screens usability\nBarcode software to ID patients and physicians\nLow-Profile wheelbase to assist getting closer to patient\nCordless charging station\nNumber of Transducer ports \nSimplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use)\n\nPerformance \nThe device will be evaluated for its ability to perform its intended function. Areas include but are not limited to: \nCapabilities to support multiple medical services \nBatter run time\nProvided Installation \nNeedle guidance system\n\nQuality/Construction/Training \nExtended Warranty \nTraining \nSecure Data encryption HIPPAA/GDPR compliant\nMeets ANSI/AAMI ES6061 Electromechanical safety standards\n\n\n\nResponses to this Sources Sought Notice shall include the following:\n\nFull name and address of company.\nSAM Unique Entity Identifier (UEI).\nBusiness Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).\nManufacturer or Distributor:\nIf distributor, provide the full name, business size and address of the manufacturer. \nIf distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. \nCountry of Origin designation for all products proposed.\nDescribe the firm s ability to provide uninterrupted supply of products on a national scale.\nTechnical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met. \nDoes respondent offer an annual service plan, Yes or No? \nIf Yes:\nDescribe what the plan covers?\nIdentify whether the plan covers software updates, parts repair/replacement, or both\nProvide literature or other documentation describing the service plan.\nIdentify whether service is provided by the OEM or a subcontractor.\n\nIdentify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number.\nItem pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. \nNOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.\nDoes your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.\nIdentify any federal contract vehicles held by your firm through which your firm can provide this equipment. \nAre there any further standards or criteria VA should consider in a procurement action for this equipment?\nAre the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.\nAny additional information the Government should know prior to issuing a solicitation.\n Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.","origin":"detail"},"contacts":[{"name":"Alanna Wilson","role":"primary","email":"Alanna.Wilson@va.gov","phone":"240-215-1633","title":"Contract Specialist"}],"place_of_performance":{"street":"Nationwide"},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"naics_codes":["334510"],"award":null,"attachments":[{"resource_id":"481dabe10c2f4e34a89ee3b3d73c1a78","name":"36C10X27Q0004.docx","kind":"file","mime_type":".docx","size_bytes":27163,"posted_at":"2026-10-02T13:17:26.629Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/481dabe10c2f4e34a89ee3b3d73c1a78/download","mirrored":false}],"awards":[],"related":[{"key":"36C10X26R0054","latest_notice_id":"cea4529a2dc946db9379e796b9acb2c3","title":"6515--NX EQ Physiologic Motility Analyzers (EndoFLIP)","solicitation_number":"36C10X26R0054","notice_type":"k","first_type":"k","first_posted":"2026-09-17","last_posted":"2026-09-17","notices":1,"due_at":"2026-10-06T14:00:00Z","due_date":"2026-10-06","closes_at":"2026-10-06T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339113","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"2-MONTH OPTION YEARS. DELIVERY IS A FOB DESTINATION","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"36C10X26R0062","latest_notice_id":"eabd804f29864ac1b4823137bf7cb05c","title":"NX EQ Monitors_Physio_Neurology_Intraop_EEG (VA-26-00045643)","solicitation_number":"36C10X26R0062","notice_type":"o","first_type":"o","first_posted":"2026-09-09","last_posted":"2026-09-29","notices":2,"due_at":"2026-10-07T16:00:00Z","due_date":"2026-10-07","closes_at":"2026-10-07T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"},{"key":"36C10X26R0048","latest_notice_id":"ee9e9d599e7a4a5eb07da8e194991ac8","title":"6515--NX EQ Hemodynamic Monitor","solicitation_number":"36C10X26R0048","notice_type":"k","first_type":"k","first_posted":"2026-09-01","last_posted":"2026-09-30","notices":3,"due_at":"2026-10-08T16:00:00Z","due_date":"2026-10-08","closes_at":"2026-10-08T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-01T04:02:27.010479Z"},{"key":"36C10X26R0047","latest_notice_id":"e4953f763897433691997580f3c46543","title":"4610--NX EQ Water Purification Systems: RO: HEMO: Portable (VA-26-00041965)","solicitation_number":"36C10X26R0047","notice_type":"p","first_type":"p","first_posted":"2026-09-24","last_posted":"2026-09-24","notices":3,"due_at":"2026-10-09T03:59:00Z","due_date":"2026-10-08","closes_at":"2026-10-09T03:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"333310","psc":"4610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-25T04:26:02.640284Z"},{"key":"36C10X26R0027","latest_notice_id":"ed8a199109044528ade7b97f1d381cb9","title":"NX EQ SURGICAL TISSUE MANAGEMENT SYSTEM","solicitation_number":"36C10X26R0027","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-23","notices":2,"due_at":"2026-10-10T03:59:00Z","due_date":"2026-10-09","closes_at":"2026-10-10T03:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":"MD","county":"24021","county_name":"Frederick County","city":"2430325","city_name":"Frederick","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T04:24:26.592861Z"}]}