{"canonical":"https://abierto.us/opportunities/15b11125q000000220001","key":"15B11125Q000000220001","url":"https://abierto.us/opportunities/15b11125q000000220001","title":"FY25 Replace UPS Control/ COMM Shop","solicitation_number":"15B11125Q000000220001","notice_type":"o","open":false,"response_deadline":"2025-11-25T17:00:00Z","first_posted":"2025-10-30","last_posted":"2025-11-24","department":"JUSTICE, DEPARTMENT OF","subagency":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office":"FCI MEMPHIS","naics":"238210","psc":"J061","set_aside":null,"place_state":"TN","place_county":"47157","place_county_name":"Shelby County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"92d7b8ebb57b45809220a50ab4e5929d","title":"FY25 Replace UPS Control/ COMM Shop","solicitation_number":"15B11125Q000000220001","notice_type":"o","base_type":"o","posted":"2025-10-30","posted_at":null,"due_at":"2025-11-13T17:00:00Z","due_date":"2025-11-13","cancelled":null,"archived":null,"archive_date":"2025-11-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/92d7b8ebb57b45809220a50ab4e5929d/view","enriched":false,"history":[]},{"notice_id":"fbb99088220f4c52b78d11a91be1efdd","title":"FY25 Replace UPS Control/ COMM Shop","solicitation_number":"15B11125Q000000220001","notice_type":"o","base_type":"o","posted":"2025-11-10","posted_at":null,"due_at":"2025-11-25T17:00:00Z","due_date":"2025-11-25","cancelled":null,"archived":null,"archive_date":"2025-12-10","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fbb99088220f4c52b78d11a91be1efdd/view","enriched":false,"history":[]},{"notice_id":"53daf8466c6447a2afeb6d903363aac4","title":"FY25 Replace UPS Control/ COMM Shop","solicitation_number":"15B11125Q000000220001","notice_type":"o","base_type":"o","posted":"2025-11-24","posted_at":null,"due_at":"2025-11-25T17:00:00Z","due_date":"2025-11-25","cancelled":null,"archived":null,"archive_date":"2025-12-10","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/53daf8466c6447a2afeb6d903363aac4/view","enriched":false,"history":[]}],"latest_notice_id":"53daf8466c6447a2afeb6d903363aac4","first_type":"o","notices":[{"dates":{"posted":"2025-10-30","response_deadline":{"raw":"2025-11-13T11:00:00-06:00","utc":"2025-11-13T17:00:00Z","date":"2025-11-13","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/92d7b8ebb57b45809220a50ab4e5929d/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"FY25 Replace UPS Control/ COMM Shop","agency":{"office":{"code":"15B111","name":"FCI MEMPHIS"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"38134","city":"MEMPHIS","state":"TN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-11-28","archive_type":"auto15"},"contacts":[{"fax":"9013845457","name":"Manuel F. Rosario","role":"primary","email":"mfrosario@bop.gov","phone":"9013845361"},{"fax":"9013845457","name":"Yourlanda Ghoston-Williams","role":"secondary","email":"yghoston-williams@bop.gov","phone":"9013725542"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"92d7b8ebb57b45809220a50ab4e5929d","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"65a4e426833b76df68e0840b0f18e12707064481e7e134ae7d22eace4f88e92c","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T17:48:36.003679Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"text":"FCI. Memphis, TN, intends to make an award to single responsible entity for the removal and installation :The contractor will provide labor, equipment and materials needed to complete the project. The contractor will complete the following: - Shut off the main power feeds to the existing electrical panels and utilize the Lock out Tag out procedures. - Disconnect the current power feeds from the one (1) old Uninterrupted Power Systems and remove them from service. - Install the 3- position switches on the load side of the UPS systems for ability to swap between the UPS and utility power source. - Install safety disconnects on the line side of the UPS systems to allow for maintenance and or replacement. - The contractor will provide one (1) Uninterrupted Power systems type 9355-30 for the Communication and Control Center. - The contractor will provide Battery cabinets type 9355-30 Part Number: KA1512100000010 for the Communication and Control Center. The battery should provide at least 90 minutes back up power for each UPS system. - The contractor will disconnect current power feeds from the one (1) Uninterrupted Power Systems and re-feed power sources to the existing panels in each area that the UPS provides protection for the Communication Room and Control Center. The Uninterrupted Power Systems specifications Qty (1) 9355-30 Model 20 AC IN: 208 VAC 4 W 50/60 HZ 3P 70 A AC OUT: 208 VAC 4 W 50/60 HZ 3P 55 A 30KW Configuration: KB2013100000110 PLEASE SEE THE ATTACHED SOW FOR FULL DETAILS","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15B11125Q000000220001","place_of_performance":{"zip":"38134","state":{"code":"TN"},"country":{"code":"USA"}},"product_service_code":"J061"},{"dates":{"posted":"2025-11-10","response_deadline":{"raw":"2025-11-25T11:00:00-06:00","utc":"2025-11-25T17:00:00Z","date":"2025-11-25","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fbb99088220f4c52b78d11a91be1efdd/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"FY25 Replace UPS Control/ COMM Shop","agency":{"office":{"code":"15B111","name":"FCI MEMPHIS"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"38134","city":"MEMPHIS","state":"TN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-12-10","archive_type":"auto15"},"contacts":[{"fax":"9013845457","name":"Manuel F. Rosario","role":"primary","email":"mfrosario@bop.gov","phone":"9013845361"},{"fax":"9013845457","name":"Yourlanda Ghoston-Williams","role":"secondary","email":"yghoston-williams@bop.gov","phone":"9013725542"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fbb99088220f4c52b78d11a91be1efdd","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"96394e0fb444f29565951780808f164290b16379e429dd07f71ec33702d06aaf","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T17:48:36.003679Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"text":"FCI. Memphis, TN, intends to make an award to single responsible entity for the removal and installation :The contractor will provide labor, equipment and materials needed to complete the project. The contractor will complete the following: - Shut off the main power feeds to the existing electrical panels and utilize the Lock out Tag out procedures. - Disconnect the current power feeds from the one (1) old Uninterrupted Power Systems and remove them from service. - Install the 3- position switches on the load side of the UPS systems for ability to swap between the UPS and utility power source. - Install safety disconnects on the line side of the UPS systems to allow for maintenance and or replacement. - The contractor will provide one (1) Uninterrupted Power systems type 9355-30 for the Communication and Control Center. - The contractor will provide Battery cabinets type 9355-30 Part Number: KA1512100000010 for the Communication and Control Center. The battery should provide at least 90 minutes back up power for each UPS system. - The contractor will disconnect current power feeds from the one (1) Uninterrupted Power Systems and re-feed power sources to the existing panels in each area that the UPS provides protection for the Communication Room and Control Center. The Uninterrupted Power Systems specifications Qty (1) 9355-30 Model 20 AC IN: 208 VAC 4 W 50/60 HZ 3P 70 A AC OUT: 208 VAC 4 W 50/60 HZ 3P 55 A 30KW Configuration: KB2013100000110 PLEASE SEE THE ATTACHED SOW FOR FULL DETAILS MODIFICATION OF SOLICITATION: INCORPORATION OF SITE VISIT, Q&A ATTACHMENT AND EXTENSION OF CLOSING DATEThis modification is issued to incorporate the following changes to the solicitation documents:1. Closing Date Extension: The closing date for bid submissions has been changed from November 13, 2025, to November 25, 2025, at 11:00 am CST.2. Voluntary Site Visit: A voluntary site visit has been scheduled.# Date and Time: November 24, 2025, at 9:30 AM CST.# Location: FCI Memphis, TN - 1101 John A. Denie Road, Memphis, TN 38134-7690.# Note: Attendance at this site visit is strictly voluntary and will not impact the evaluation of any bids submitted prior to the revised closing date.3. Site Visit Registration Requirement: Vendors interested in participating in the site visit must complete the attached NCIC check form and submit it via email to Mr. Flanagan, General Foreman at Wflanagan@bop.gov. The deadline for registration is November 19, 2025, at 11:00 AM CST (close of business).4. Q&A attachment All other terms and conditions of the original solicitation remain unchanged.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15B11125Q000000220001","place_of_performance":{"zip":"38134","state":{"code":"TN"},"country":{"code":"USA"}},"product_service_code":"J061"},{"dates":{"posted":"2025-11-24","response_deadline":{"raw":"2025-11-25T11:00:00-06:00","utc":"2025-11-25T17:00:00Z","date":"2025-11-25","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/53daf8466c6447a2afeb6d903363aac4/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"FY25 Replace UPS Control/ COMM Shop","agency":{"office":{"code":"15B111","name":"FCI MEMPHIS"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"38134","city":"MEMPHIS","state":"TN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-12-10","archive_type":"auto15"},"contacts":[{"fax":"9013845457","name":"Manuel F. Rosario","role":"primary","email":"mfrosario@bop.gov","phone":"9013845361"},{"fax":"9013845457","name":"Yourlanda Ghoston-Williams","role":"secondary","email":"yghoston-williams@bop.gov","phone":"9013725542"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"53daf8466c6447a2afeb6d903363aac4","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"474ed15d50c2132ff3404517bdbbdba7073070f7d7659b94ae6648731449fd19","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T17:48:36.003679Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"text":"FCI. Memphis, TN, intends to make an award to single responsible entity for the removal and installation :The contractor will provide labor, equipment and materials needed to complete the project. The contractor will complete the following: - Shut off the main power feeds to the existing electrical panels and utilize the Lock out Tag out procedures. - Disconnect the current power feeds from the one (1) old Uninterrupted Power Systems and remove them from service. - Install the 3- position switches on the load side of the UPS systems for ability to swap between the UPS and utility power source. - Install safety disconnects on the line side of the UPS systems to allow for maintenance and or replacement. - The contractor will provide one (1) Uninterrupted Power systems type 9355-30 for the Communication and Control Center. - The contractor will provide Battery cabinets type 9355-30 Part Number: KA1512100000010 for the Communication and Control Center. The battery should provide at least 90 minutes back up power for each UPS system. - The contractor will disconnect current power feeds from the one (1) Uninterrupted Power Systems and re-feed power sources to the existing panels in each area that the UPS provides protection for the Communication Room and Control Center. The Uninterrupted Power Systems specifications Qty (1) 9355-30 Model 20 AC IN: 208 VAC 4 W 50/60 HZ 3P 70 A AC OUT: 208 VAC 4 W 50/60 HZ 3P 55 A 30KW Configuration: KB2013100000110 PLEASE SEE THE ATTACHED SOW FOR FULL DETAILS MODIFICATION OF SOLICITATION: INCORPORATION OF SITE VISIT, Q&A ATTACHMENT AND EXTENSION OF CLOSING DATEThis modification is issued to incorporate the following changes to the solicitation documents:1. Closing Date Extension: The closing date for bid submissions has been changed from November 13, 2025, to November 25, 2025, at 11:00 am CST.2. Voluntary Site Visit: A voluntary site visit has been scheduled.# Date and Time: November 24, 2025, at 9:30 AM CST.# Location: FCI Memphis, TN - 1101 John A. Denie Road, Memphis, TN 38134-7690.# Note: Attendance at this site visit is strictly voluntary and will not impact the evaluation of any bids submitted prior to the revised closing date.3. Site Visit Registration Requirement: Vendors interested in participating in the site visit must complete the attached NCIC check form and submit it via email to Mr. Flanagan, General Foreman at Wflanagan@bop.gov. The deadline for registration is November 19, 2025, at 11:00 AM CST (close of business).4. Q&A attachment All other terms and conditions of the original solicitation remain unchanged.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15B11125Q000000220001","place_of_performance":{"zip":"38134","state":{"code":"TN"},"country":{"code":"USA"}},"product_service_code":"J061"}],"due_at":"2025-11-25T17:00:00Z","due_date":"2025-11-25","closes_at":"2025-11-25T17:00:00Z","awardable":true,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15B111","office_name":"FCI MEMPHIS","state":"TN","county":"47157","county_name":"Shelby County","city":null,"city_name":null,"country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"53daf8466c6447a2afeb6d903363aac4","description":{"text":"FCI. Memphis, TN, intends to make an award to single responsible entity for the removal and installation :The contractor will provide labor, equipment and materials needed to complete the project. The contractor will complete the following: - Shut off the main power feeds to the existing electrical panels and utilize the Lock out Tag out procedures. - Disconnect the current power feeds from the one (1) old Uninterrupted Power Systems and remove them from service. - Install the 3- position switches on the load side of the UPS systems for ability to swap between the UPS and utility power source. - Install safety disconnects on the line side of the UPS systems to allow for maintenance and or replacement. - The contractor will provide one (1) Uninterrupted Power systems type 9355-30 for the Communication and Control Center. - The contractor will provide Battery cabinets type 9355-30 Part Number: KA1512100000010 for the Communication and Control Center. The battery should provide at least 90 minutes back up power for each UPS system. - The contractor will disconnect current power feeds from the one (1) Uninterrupted Power Systems and re-feed power sources to the existing panels in each area that the UPS provides protection for the Communication Room and Control Center. The Uninterrupted Power Systems specifications Qty (1) 9355-30 Model 20 AC IN: 208 VAC 4 W 50/60 HZ 3P 70 A AC OUT: 208 VAC 4 W 50/60 HZ 3P 55 A 30KW Configuration: KB2013100000110 PLEASE SEE THE ATTACHED SOW FOR FULL DETAILS MODIFICATION OF SOLICITATION: INCORPORATION OF SITE VISIT, Q&A ATTACHMENT AND EXTENSION OF CLOSING DATEThis modification is issued to incorporate the following changes to the solicitation documents:1. Closing Date Extension: The closing date for bid submissions has been changed from November 13, 2025, to November 25, 2025, at 11:00 am CST.2. Voluntary Site Visit: A voluntary site visit has been scheduled.# Date and Time: November 24, 2025, at 9:30 AM CST.# Location: FCI Memphis, TN - 1101 John A. Denie Road, Memphis, TN 38134-7690.# Note: Attendance at this site visit is strictly voluntary and will not impact the evaluation of any bids submitted prior to the revised closing date.3. Site Visit Registration Requirement: Vendors interested in participating in the site visit must complete the attached NCIC check form and submit it via email to Mr. Flanagan, General Foreman at Wflanagan@bop.gov. The deadline for registration is November 19, 2025, at 11:00 AM CST (close of business).4. Q&A attachment All other terms and conditions of the original solicitation remain unchanged.","html":null,"origin":"extract"},"contacts":[{"fax":"9013845457","name":"Manuel F. Rosario","role":"primary","email":"mfrosario@bop.gov","phone":"9013845361"},{"fax":"9013845457","name":"Yourlanda Ghoston-Williams","role":"secondary","email":"yghoston-williams@bop.gov","phone":"9013725542"}],"place_of_performance":{"zip":"38134","state":{"code":"TN"},"country":{"code":"USA"}},"office_address":{"zip":"38134","city":"MEMPHIS","state":"TN","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[],"awards":[],"related":[]}