{"canonical":"https://abierto.us/opportunities/12405b24q0075","key":"12405B24Q0075","url":"https://abierto.us/opportunities/12405b24q0075","title":"LI-600PF Porometer/Fluorometer","solicitation_number":"12405B24Q0075","notice_type":"k","open":false,"response_deadline":"2024-02-09T22:00:00Z","first_posted":"2024-02-01","last_posted":"2024-02-01","department":"AGRICULTURE, DEPARTMENT OF","subagency":"AGRICULTURAL RESEARCH SERVICE","office":"USDA ARS SEA AAO ACQ/PER PROP","naics":"334516","psc":"6640","set_aside":null,"place_state":"PR","place_county":"72097","place_county_name":"Mayagüez Municipio","place_city":"7252431","place_city_name":"Mayagüez","winner":"LI-COR, INC.","award_amount":null,"publications":[{"notice_id":"cbc180acc4c242ddb84f822a7dab45c5","title":"LI-600PF Porometer/Fluorometer","solicitation_number":"12405B24Q0075","notice_type":"k","base_type":"k","posted":"2024-02-01","posted_at":null,"due_at":"2024-02-09T22:00:00Z","due_date":"2024-02-09","cancelled":null,"archived":null,"archive_date":"2024-02-24","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cbc180acc4c242ddb84f822a7dab45c5/view","enriched":false,"history":[]}],"latest_notice_id":"cbc180acc4c242ddb84f822a7dab45c5","first_type":"k","notices":[{"dates":{"posted":"2024-02-01","response_deadline":{"raw":"2024-02-09T16:00:00-06:00","utc":"2024-02-09T22:00:00Z","date":"2024-02-09","time":"16:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cbc180acc4c242ddb84f822a7dab45c5/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"LI-600PF Porometer/Fluorometer","agency":{"office":{"code":"12405B","name":"USDA ARS SEA AAO ACQ/PER PROP"},"subtier":{"code":"12H2","name":"AGRICULTURAL RESEARCH SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"38776","city":"STONEVILLE","state":"MS","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-02-24","archive_type":"auto15"},"contacts":[{"name":"Cecilia McNamee","role":"primary","email":"cecilia.mcnamee@usda.gov","phone":"9852328289"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cbc180acc4c242ddb84f822a7dab45c5","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"2e86f4faac4fe941c79ea43fa8e3ac15502926b44f8d4de4584495625b60a562","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"List of equipment specifications: The instrument must have the option to do both stomatal conductance and chlorophyll fluorescence on the same leaf area. Built in Photosynthetically Active Radiation (PAR) sensor measures ambient light with each measurement. Built in accelerometer/magnetometer to measure heading, pitch, and roll. Built in GPS to record latitude, longitude, and altitude with every measurement. Software calculates leaf angle of incident with data from accelerometer/magnetometer and GPS. The instrument must have an internal bar code scanner to help with both repetition speed and data organization. The instrument must include a software application to configure, calibrate, download and stream data. The instrument desktop software must include a barcode generator for creating custom barcode labels. The instrument must include a tripod mount for teaching and lab studies. The instrument must be able to take a combined stomatal conductance and chlorophyll fluorescence measurement in less than 10 seconds. The instrument aperture size must be 0.76 cm diameter to ensure the majority of leaf area morphologies can be measured. Infrared leaf temperature (IRT) sensor eliminates the leaf contact point. The instrument must be ergonomic and lightweight (<2lbs) for effortless measurements all day. The instrument must have a display to show the instrument status and the last measurement. The instrument must contain internal Lithium/Ion batteries for 8 hours of nominal operation. The measurements must be made with one handed operation without a separate console. Fluorometer must have options for both rectangular and multiphase flash events.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12405B24Q0075","place_of_performance":{"zip":"00680","city":{"name":"Mayaguez"},"state":{"code":"PR"},"country":{"code":"USA"}},"product_service_code":"6640"}],"due_at":"2024-02-09T22:00:00Z","due_date":"2024-02-09","closes_at":"2024-02-09T22:00:00Z","awardable":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-12405B","office_name":"USDA ARS SEA AAO ACQ/PER PROP","state":"PR","county":"72097","county_name":"Mayagüez Municipio","city":"7252431","city_name":"Mayagüez","country":"USA","winner_key":"GTDVYFYXCFF7","amount":null,"linked_awards":1,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"cbc180acc4c242ddb84f822a7dab45c5","description":{"text":"List of equipment specifications: The instrument must have the option to do both stomatal conductance and chlorophyll fluorescence on the same leaf area. Built in Photosynthetically Active Radiation (PAR) sensor measures ambient light with each measurement. Built in accelerometer/magnetometer to measure heading, pitch, and roll. Built in GPS to record latitude, longitude, and altitude with every measurement. Software calculates leaf angle of incident with data from accelerometer/magnetometer and GPS. The instrument must have an internal bar code scanner to help with both repetition speed and data organization. The instrument must include a software application to configure, calibrate, download and stream data. The instrument desktop software must include a barcode generator for creating custom barcode labels. The instrument must include a tripod mount for teaching and lab studies. The instrument must be able to take a combined stomatal conductance and chlorophyll fluorescence measurement in less than 10 seconds. The instrument aperture size must be 0.76 cm diameter to ensure the majority of leaf area morphologies can be measured. Infrared leaf temperature (IRT) sensor eliminates the leaf contact point. The instrument must be ergonomic and lightweight (<2lbs) for effortless measurements all day. The instrument must have a display to show the instrument status and the last measurement. The instrument must contain internal Lithium/Ion batteries for 8 hours of nominal operation. The measurements must be made with one handed operation without a separate console. Fluorometer must have options for both rectangular and multiphase flash events.","html":null,"origin":"extract"},"contacts":[{"name":"Cecilia McNamee","role":"primary","email":"cecilia.mcnamee@usda.gov","phone":"9852328289"}],"place_of_performance":{"zip":"00680","city":{"name":"Mayaguez"},"state":{"code":"PR"},"country":{"code":"USA"}},"office_address":{"zip":"38776","city":"STONEVILLE","state":"MS","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_12405B24P0070_12H2_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_12405B24P0070_12H2_-NONE-_-NONE-/","piid":"12405B24P0070","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"GTDVYFYXCFF7","recipient_name":"LI-COR, INC.","recipient_uei":"GTDVYFYXCFF7","recipient_cage":"0WXR3","recipient_city":"LINCOLN","recipient_state":"NE","sub_name":"Agricultural Research Service","office_name":"USDA ARS SEA AAO ACQ/PER PROP","office_key":"o-12405B","first_action_date":"2024-02-28","last_action_date":"2024-02-28","actions":1,"obligated":"14029.09","current_total_value":"14029.09","potential_total_value":"14029.09","naics":"334516","psc":"6640","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":5,"description":"THE INSTRUMENT MUST HAVE THE OPTION TO DO BOTH STOMATAL CONDUCTANCE AND CHLOROPHYLL FLUORESCENCE ON THE SAME LEAF AREA.","method":"solicitation","confidence":"high","evidence":["solicitation number 12405B24Q0075 equals the FPDS solicitation identifier","same awarding office 12405B"],"opportunity_key":null,"opportunity_title":null}],"related":[]}