{"canonical":"https://abierto.us/opportunities/003001","key":"003001","url":"https://abierto.us/opportunities/003001","title":"Ventilation System Components","solicitation_number":"003-001","notice_type":"r","open":false,"response_deadline":"2026-03-20T21:00:00Z","first_posted":"2026-03-11","last_posted":"2026-03-11","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"UCOR – DOE CONTRACTOR","naics":"333413","psc":"4460","set_aside":null,"place_state":"TN","place_county":null,"place_county_name":null,"place_city":"4755120","place_city_name":"Oak Ridge","winner":null,"award_amount":null,"publications":[{"notice_id":"8e0b95adaafc41ab93f1441c3bb4efe6","title":"Ventilation System Components","solicitation_number":"003-001","notice_type":"r","base_type":"r","posted":"2026-03-11","posted_at":null,"due_at":"2026-03-20T21:00:00Z","due_date":"2026-03-20","cancelled":null,"archived":null,"archive_date":"2026-03-20","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8e0b95adaafc41ab93f1441c3bb4efe6/view","enriched":false,"history":[]}],"latest_notice_id":"8e0b95adaafc41ab93f1441c3bb4efe6","first_type":"r","notices":[{"dates":{"posted":"2026-03-11","response_deadline":{"raw":"2026-03-20T17:00:00-04:00","utc":"2026-03-20T21:00:00Z","date":"2026-03-20","time":"17:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8e0b95adaafc41ab93f1441c3bb4efe6/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilation System Components","agency":{"office":{"code":"899044","name":"UCOR – DOE CONTRACTOR"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"37830","city":"Oak Ridge","state":"TN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-03-20","archive_type":"auto_custom"},"contacts":[{"name":"Michael Fuson","role":"primary","email":"Michael.Fuson@orcc.doe.gov","phone":"(865)385-2336"},{"name":"Diana Osbourne","role":"secondary","email":"Diana.Osbourne@orcc.doe.gov","phone":"8598934104"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"8e0b95adaafc41ab93f1441c3bb4efe6","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"2e67c839151953e12091b17f027f8ecf1fcadf7d6298d7b3d3dc23109cf71876","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"United Cleanup Oak Ridge (UCOR) requires information on ventilation system components with the following specifications for an approximately 475,200 cubic feet volume: Exhaust approximately 60,000 cubic feet per minute (cfm) 7 air changes per hour The system requires the use of HEPA filtration with the following requirements: Nuclear Grade 99.97% Filter Ability to Bag in and Bag Out Pre Filter 0.3 micron Please provide the following for available options: Louvers Physical Dimensions (Diameter or Length x Width x Height and Weight) Installation Means and Price (Frames or Hangers) Prefer gravity damper Fans Physical Dimensions (Diameter or Length x Width x Height and Weight) Installation Means and Price (Frames or Hangers) Electrical Power Requirements (Voltage and Phase) Ducting Installation Means and Price (Hangers) HEPA Filter Units Physical Dimensions (Length x Width x Height and Weight)","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"003-001","place_of_performance":{"zip":"37831","city":{"name":"Oak Ridge"},"state":{"code":"TN"},"country":{"code":"USA"}},"product_service_code":"4460"}],"due_at":"2026-03-20T21:00:00Z","due_date":"2026-03-20","closes_at":"2026-03-20T21:00:00Z","awardable":true,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899044","office_name":"UCOR – DOE CONTRACTOR","state":"TN","county":null,"county_name":null,"city":"4755120","city_name":"Oak Ridge","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"8e0b95adaafc41ab93f1441c3bb4efe6","description":{"text":"United Cleanup Oak Ridge (UCOR) requires information on ventilation system components with the following specifications for an approximately 475,200 cubic feet volume: Exhaust approximately 60,000 cubic feet per minute (cfm) 7 air changes per hour The system requires the use of HEPA filtration with the following requirements: Nuclear Grade 99.97% Filter Ability to Bag in and Bag Out Pre Filter 0.3 micron Please provide the following for available options: Louvers Physical Dimensions (Diameter or Length x Width x Height and Weight) Installation Means and Price (Frames or Hangers) Prefer gravity damper Fans Physical Dimensions (Diameter or Length x Width x Height and Weight) Installation Means and Price (Frames or Hangers) Electrical Power Requirements (Voltage and Phase) Ducting Installation Means and Price (Hangers) HEPA Filter Units Physical Dimensions (Length x Width x Height and Weight)","html":null,"origin":"extract"},"contacts":[{"name":"Michael Fuson","role":"primary","email":"Michael.Fuson@orcc.doe.gov","phone":"(865)385-2336"},{"name":"Diana Osbourne","role":"secondary","email":"Diana.Osbourne@orcc.doe.gov","phone":"8598934104"}],"place_of_performance":{"zip":"37831","city":{"name":"Oak Ridge"},"state":{"code":"TN"},"country":{"code":"USA"}},"office_address":{"zip":"37830","city":"Oak Ridge","state":"TN","country":"USA"},"naics_codes":["333413"],"award":null,"attachments":[],"awards":[],"related":[]}